CVE-2024-11013
Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21
- Anyone running NEC Corporation UNIVERGE IX for Ver10.8 up to Ver10.8.27
- Anyone running NEC Corporation UNIVERGE IX for Ver10.9 up to Ver10.9.14
- Anyone running NEC Corporation UNIVERGE IX-R/IX-V Ver1.2.15 and earlier
Vulnerability facts
- Affected
- NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21; NEC Corporation UNIVERGE IX for Ver10.8 up to Ver10.8.27; NEC Corporation UNIVERGE IX for Ver10.9 up to Ver10.9.14; NEC Corporation UNIVERGE IX-R/IX-V Ver1.2.15 and earlier
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 7.2 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 1.78% chance of exploitation in 30 days (percentile 79, 2026-11-26)
- CWE
- CWE-77
- Modified
Description
Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| NEC Corporation UNIVERGE IX | from Ver9.2 to Ver10.10.21 | — | cvelist |
| NEC Corporation UNIVERGE IX | for Ver10.8 up to Ver10.8.27 | — | cvelist |
| NEC Corporation UNIVERGE IX | for Ver10.9 up to Ver10.9.14 | — | cvelist |
| NEC Corporation UNIVERGE IX-R/IX-V | Ver1.2.15 and earlier | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-11013. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-11013.md Affected: NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21; NEC Corporation UNIVERGE IX for Ver10.8 up to Ver10.8.27; NEC Corporation UNIVERGE IX for Ver10.9 up to Ver10.9.14; NEC Corporation UNIVERGE IX-R/IX-V Ver1.2.15 and earlier Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for NEC Corporation UNIVERGE IX, NEC Corporation UNIVERGE IX-R/IX-V: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-11013 being exploited?
There is no confirmed exploitation: CVE-2024-11013 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.78% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-11013?
High: CVSS 7.2 (v3.1, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2024-11013?
NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21; NEC Corporation UNIVERGE IX for Ver10.8 up to Ver10.8.27; NEC Corporation UNIVERGE IX for Ver10.9 up to Ver10.9.14; NEC Corporation UNIVERGE IX-R/IX-V Ver1.2.15 and earlier.
Is there a fix for CVE-2024-11013?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-11013?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.