CVE-2024-10313
iniNet Solutions SpiderControl SCADA PC HMI Editor Path Traversal
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running iniNet Solutions SpiderControl SCADA PC HMI Editor 8.10.00.00
Vulnerability facts
- Affected
- iniNet Solutions SpiderControl SCADA PC HMI Editor 8.10.00.00
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 8.6 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: Passive
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.88% chance of exploitation in 30 days (percentile 57, 2026-11-26)
- CWE
- CWE-22
- Modified
Description
iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| iniNet Solutions SpiderControl SCADA PC HMI Editor | 8.10.00.00 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2024-10313. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2024-10313.md Affected: iniNet Solutions SpiderControl SCADA PC HMI Editor 8.10.00.00 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for iniNet Solutions SpiderControl SCADA PC HMI Editor: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2024-10313 being exploited?
There is no confirmed exploitation: CVE-2024-10313 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.88% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2024-10313?
High: CVSS 8.6 (v4.0, scored by CNA). Remote, login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2024-10313?
iniNet Solutions SpiderControl SCADA PC HMI Editor 8.10.00.00.
Is there a fix for CVE-2024-10313?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2024-10313?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.