CVE-2024-0802

CRITICAL 9.8EPSS 77%

Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modu…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q03UDECPU The first 5 digits of serial No. "26061" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q04UDEHCPU The first 5 digits of serial No. "26061" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q06UDEHCPU The first 5 digits of serial No. "26061" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q10UDEHCPU The first 5 digits of serial No. "26061" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q13UDEHCPU The first 5 digits of serial No. "26061" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q20UDEHCPU The first 5 digits of serial No. "26061" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q26UDEHCPU The first 5 digits of serial No. "26061" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC-Q Series Q50UDEHCPU The first 5 digits of serial No. "26061" and prior

Vulnerability facts

Affected
Mitsubishi Electric Corporation MELSEC-Q Series Q03UDECPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q04UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q06UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q10UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q13UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q20UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q26UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q50UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q100UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q03UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q04UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q06UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q13UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q26UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q04UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q06UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q13UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q26UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-L Series L02CPU The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L06CPU The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L02CPU-P The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L06CPU-P The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU-P The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU-BT The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU-PBT The first 5 digits of serial No. "26041" and prior
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.8 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
1.63% chance of exploitation in 30 days (percentile 77, 2026-11-26)
CWE
CWE-468
Published
Modified

Description

Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet.

Affected and fixed versions

Package / productAffectedFixedSource
Mitsubishi Electric Corporation MELSEC-Q Series Q03UDECPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q04UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q06UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q10UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q13UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q20UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q26UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q50UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q100UDEHCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q03UDVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q04UDVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q06UDVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q13UDVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q26UDVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q04UDPVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q06UDPVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q13UDPVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-Q Series Q26UDPVCPUThe first 5 digits of serial No. "26061" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L02CPUThe first 5 digits of serial No. "26041" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L06CPUThe first 5 digits of serial No. "26041" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L26CPUThe first 5 digits of serial No. "26041" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L02CPU-PThe first 5 digits of serial No. "26041" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L06CPU-PThe first 5 digits of serial No. "26041" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L26CPU-PThe first 5 digits of serial No. "26041" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L26CPU-BTThe first 5 digits of serial No. "26041" and prior—cvelist
Mitsubishi Electric Corporation MELSEC-L Series L26CPU-PBTThe first 5 digits of serial No. "26041" and prior—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2024-0802. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2024-0802.md
Affected: Mitsubishi Electric Corporation MELSEC-Q Series Q03UDECPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q04UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q06UDEHCPU The first 5 digits …
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Mitsubishi Electric Corporation MELSEC-Q Series Q03UDECPU, Mitsubishi Electric Corporation MELSEC-Q Series Q04UDEHCPU, Mitsubishi Electric Corporation MELSEC-Q Series Q06UDEHCPU, Mitsubishi Electric Corporation MELSEC-Q Series Q10UDEHCPU, Mitsubishi Electric Corporation MELSEC-Q Series Q13UDEHCPU, …: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2024-0802 being exploited?

There is no confirmed exploitation: CVE-2024-0802 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.63% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2024-0802?

Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2024-0802?

Mitsubishi Electric Corporation MELSEC-Q Series Q03UDECPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q04UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q06UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q10UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q13UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q20UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q26UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q50UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q100UDEHCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q03UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q04UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q06UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q13UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q26UDVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q04UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q06UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q13UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-Q Series Q26UDPVCPU The first 5 digits of serial No. "26061" and prior; Mitsubishi Electric Corporation MELSEC-L Series L02CPU The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L06CPU The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L02CPU-P The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L06CPU-P The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU-P The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU-BT The first 5 digits of serial No. "26041" and prior; Mitsubishi Electric Corporation MELSEC-L Series L26CPU-PBT The first 5 digits of serial No. "26041" and prior.

Is there a fix for CVE-2024-0802?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2024-0802?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors