# CVE-2023-7066: Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.3
- **CVSS:** 7.3 (v4.0, CNA) `CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Local; Attack complexity: High; Attack requirements: None; Privileges required: None; User interaction: Passive; Confidentiality impact: High; Integrity impact: High; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.27% (percentile 12, 2026-11-26)
- **CWE:** CWE-125
- **Published:** 2024-08-12T21:46:38.910Z
- **Modified:** 2026-06-17T06:51:59.360Z

## Who should check

- Anyone running Siemens JT2Go \< V14.3.0.8
- Anyone running Siemens Teamcenter Visualization \< V14.1.0.14; \< V14.2.0.10; \< V14.3.0.8; \< V2312.0002

## Description

The affected applications contain an out of bounds read past the end of 
an allocated structure while parsing specially crafted PDF files. This 
could allow an attacker to execute code in the context of the current 
process.

## Affected and fixed versions

- Siemens JT2Go: \< V14.3.0.8 (cvelist)
- Siemens Teamcenter Visualization: \< V14.1.0.14; \< V14.2.0.10; \< V14.3.0.8; \< V2312.0002 (cvelist)

## Mitigation

- Vendor workaround: To reduce risk, Siemens 
- recommends users not open untrusted PDF files in affected applications.
- 
- 
- 
- 
- 
- 
- As a general security measure, Siemens recommends protecting network 
- access to devices with appropriate mechanisms. To operate the devices in
-  a protected IT environment, Siemens recommends configuring the 
- environment according to  Siemens' operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security  and following recommendations in the product manuals.
- 
- 
- Additional information on industrial security by Siemens can be found on the  Siemens industrial security webpage https://www.siemens.com/industrialsecurity 
- 
- For more information see the associated Siemens security advisory SSA-722010

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2023-7066. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-7066.md
Affected: Siemens JT2Go < V14.3.0.8; Siemens Teamcenter Visualization < V14.1.0.14; < V14.2.0.10; < V14.3.0.8; < V2312.0002
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens JT2Go, Siemens Teamcenter Visualization: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2023-7066 being exploited?

There is no confirmed exploitation: CVE-2023-7066 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.27% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2023-7066?

High: CVSS 7.3 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work. The attack needs conditions outside the attacker's control, which makes it harder.

### Which versions are affected by CVE-2023-7066?

Siemens JT2Go \< V14.3.0.8; Siemens Teamcenter Visualization \< V14.1.0.14; \< V14.2.0.10; \< V14.3.0.8; \< V2312.0002.

### Is there a fix for CVE-2023-7066?

No fixed version is listed in the sources yet. Vendor workaround: To reduce risk, Siemens  recommends users not open untrusted PDF files in affected applications.       As a general security measure, Siemens recommends protecting network  access to devices with appropriate mechanisms. To operate the devices in  a protected IT environment, Siemens recommends configuring the  environment according to  Siemens' operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security  and following recommendations in the product manuals.   Additional information on industrial security by Siemens can be found on the  Siemens industrial security webpage https://www.siemens.com/industrialsecurity   For more information see the associated Siemens security advisory SSA-722010

### How do I check if I'm affected by CVE-2023-7066?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert-portal.siemens.com/productcert/html/ssa-722010.html>
- other: <https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-03>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2023-7066>

HTML: <https://flawdb.com/CVE-2023-7066> · JSON: <https://flawdb.com/api/v1/entries/CVE-2023-7066>