Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2023-5986

HIGH 8.2EPSS 38%

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Schneider Electric EcoStruxure Power Monitoring Expert (PME) Version 2020 CU2 and prior; Version 2021 CU1 and prior
  • Anyone running Schneider Electric EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021; Advanced Reporting and Dashboards Module 2020 prior to CU3
  • Anyone running Schneider Electric EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2

Vulnerability facts

Affected
Schneider Electric EcoStruxure Power Monitoring Expert (PME) Version 2020 CU2 and prior; Version 2021 CU1 and prior; Schneider Electric EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021; Advanced Reporting and Dashboards Module 2020 prior to CU3; Schneider Electric EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
8.2 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: Required
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: High
  • Integrity impact: Low
  • Availability impact: None
EPSS
0.52% chance of exploitation in 30 days (percentile 38, 2026-11-26)
CWE
CWE-601
Published
Modified

Description

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.

Affected and fixed versions

Package / productAffectedFixedSource
Schneider Electric EcoStruxure Power Monitoring Expert (PME)Version 2020 CU2 and prior; Version 2021 CU1 and prior—cvelist
Schneider Electric EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards ModuleAdvanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021; Advanced Reporting and Dashboards Module 2020 prior to CU3—cvelist
Schneider Electric EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards ModuleEcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2023-5986. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-5986.md
Affected: Schneider Electric EcoStruxure Power Monitoring Expert (PME) Version 2020 CU2 and prior; Version 2021 CU1 and prior; Schneider Electric EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Opera…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric EcoStruxure Power Monitoring Expert (PME), Schneider Electric EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module, Schneider Electric EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2023-5986 being exploited?

There is no confirmed exploitation: CVE-2023-5986 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.52% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2023-5986?

High: CVSS 8.2 (v3.1, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2023-5986?

Schneider Electric EcoStruxure Power Monitoring Expert (PME) Version 2020 CU2 and prior; Version 2021 CU1 and prior; Schneider Electric EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021; Advanced Reporting and Dashboards Module 2020 prior to CU3; Schneider Electric EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2.

Is there a fix for CVE-2023-5986?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2023-5986?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors