CVE-2023-52891
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIMATIC Energy Manager Basic < V7.5
- Anyone running Siemens SIMATIC Energy Manager PRO < V7.5
- Anyone running Siemens SIMATIC IPC DiagBase < *
- Anyone running Siemens SIMATIC IPC DiagMonitor < *
- Anyone running Siemens SIMIT V10 < *
- Anyone running Siemens SIMIT V11 < V11.1
Vulnerability facts
- Affected
- Siemens SIMATIC Energy Manager Basic < V7.5; Siemens SIMATIC Energy Manager PRO < V7.5; Siemens SIMATIC IPC DiagBase < *; Siemens SIMATIC IPC DiagMonitor < *; Siemens SIMIT V10 < *; Siemens SIMIT V11 < V11.1
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.3 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Low
- EPSS
- 0.71% chance of exploitation in 30 days (percentile 49, 2026-11-26)
- CWE
- CWE-1325
- Modified
Description
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-52891. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-52891.md Affected: Siemens SIMATIC Energy Manager Basic < V7.5; Siemens SIMATIC Energy Manager PRO < V7.5; Siemens SIMATIC IPC DiagBase < *; Siemens SIMATIC IPC DiagMonitor < *; Siemens SIMIT V10 < *; Siemens SIMIT V11 < V11.1 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIMATIC Energy Manager Basic, Siemens SIMATIC Energy Manager PRO, Siemens SIMATIC IPC DiagBase, Siemens SIMATIC IPC DiagMonitor, Siemens SIMIT V10, Siemens SIMIT V11: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-52891 being exploited?
There is no confirmed exploitation: CVE-2023-52891 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.71% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-52891?
Medium: CVSS 5.3 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2023-52891?
Siemens SIMATIC Energy Manager Basic < V7.5; Siemens SIMATIC Energy Manager PRO < V7.5; Siemens SIMATIC IPC DiagBase < *; Siemens SIMATIC IPC DiagMonitor < *; Siemens SIMIT V10 < *; Siemens SIMIT V11 < V11.1.
Is there a fix for CVE-2023-52891?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2023-52891?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.