CVE-2023-41255
The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Rexroth ctrlX HMI Web Panel - WR21 (WR2107) all
- Anyone running Rexroth ctrlX HMI Web Panel - WR21 (WR2110) all
- Anyone running Rexroth ctrlX HMI Web Panel - WR21 (WR2115) all
Vulnerability facts
- Affected
- Rexroth ctrlX HMI Web Panel - WR21 (WR2107) all; Rexroth ctrlX HMI Web Panel - WR21 (WR2110) all; Rexroth ctrlX HMI Web Panel - WR21 (WR2115) all
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.8 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.50% chance of exploitation in 30 days (percentile 36, 2026-11-26)
- CWE
- CWE-306
- Modified
Description
The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication of the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-41255. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-41255.md Affected: Rexroth ctrlX HMI Web Panel - WR21 (WR2107) all; Rexroth ctrlX HMI Web Panel - WR21 (WR2110) all; Rexroth ctrlX HMI Web Panel - WR21 (WR2115) all Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Rexroth ctrlX HMI Web Panel - WR21 (WR2107), Rexroth ctrlX HMI Web Panel - WR21 (WR2110), Rexroth ctrlX HMI Web Panel - WR21 (WR2115): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2023-41255 being exploited?
There is no confirmed exploitation: CVE-2023-41255 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.50% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-41255?
High: CVSS 8.8 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2023-41255?
Rexroth ctrlX HMI Web Panel - WR21 (WR2107) all; Rexroth ctrlX HMI Web Panel - WR21 (WR2110) all; Rexroth ctrlX HMI Web Panel - WR21 (WR2115) all.