CVE-2023-39461
Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Triangle MicroWorks SCADA Data Gateway 5.1.3.20324
Vulnerability facts
- Affected
- Triangle MicroWorks SCADA Data Gateway 5.1.3.20324
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 4.4 (v3.0, CNA)CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: High
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- EPSS
- 1.15% chance of exploitation in 30 days (percentile 67, 2026-11-26)
- CWE
- CWE-117
- Modified
Description
Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Triangle MicroWorks SCADA Data Gateway | 5.1.3.20324 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-39461. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-39461.md Affected: Triangle MicroWorks SCADA Data Gateway 5.1.3.20324 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Triangle MicroWorks SCADA Data Gateway: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-39461 being exploited?
There is no confirmed exploitation: CVE-2023-39461 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.15% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-39461?
Medium: CVSS 4.4 (v3.0, scored by CNA). Remote, login needed. The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2023-39461?
Triangle MicroWorks SCADA Data Gateway 5.1.3.20324.
Is there a fix for CVE-2023-39461?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2023-39461?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.