CVE-2023-37545
CODESYS: Improper Input Validation in CmpApp component
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running CODESYS Control for BeagleBone SL < V4.10.0.0
- Anyone running CODESYS Control for emPC-A/iMX6 SL < V4.10.0.0
- Anyone running CODESYS Control for IOT2000 SL < V4.10.0.0
- Anyone running CODESYS Control for Linux SL < V4.10.0.0
- Anyone running CODESYS Control for PFC100 SL < V4.10.0.0
- Anyone running CODESYS Control for PFC200 SL < V4.10.0.0
- Anyone running CODESYS Control for PLCnext SL < V4.10.0.0
- Anyone running CODESYS Control for Raspberry Pi SL < V4.10.0.0
Vulnerability facts
- Affected
- CODESYS Control for BeagleBone SL < V4.10.0.0; CODESYS Control for emPC-A/iMX6 SL < V4.10.0.0; CODESYS Control for IOT2000 SL < V4.10.0.0; CODESYS Control for Linux SL < V4.10.0.0; CODESYS Control for PFC100 SL < V4.10.0.0; CODESYS Control for PFC200 SL < V4.10.0.0; CODESYS Control for PLCnext SL < V4.10.0.0; CODESYS Control for Raspberry Pi SL < V4.10.0.0; CODESYS Control for WAGO Touch Panels 600 SL < V4.10.0.0; CODESYS Control RTE (for Beckhoff CX) SL < V3.5.19.20; CODESYS Control RTE (SL) < V3.5.19.20; CODESYS Control Runtime System Toolkit < V3.5.19.20; CODESYS Control Win (SL) < V3.5.19.20; CODESYS Development System V3 < V3.5.19.20; CODESYS HMI (SL) < V3.5.19.20; CODESYS Safety SIL2 Runtime Toolkit < V3.5.19.20
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 6.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: Low
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 0.83% chance of exploitation in 30 days (percentile 55, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| CODESYS Control for BeagleBone SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for emPC-A/iMX6 SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for IOT2000 SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for Linux SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for PFC100 SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for PFC200 SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for PLCnext SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for Raspberry Pi SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control for WAGO Touch Panels 600 SL | < V4.10.0.0 | — | cvelist |
| CODESYS Control RTE (for Beckhoff CX) SL | < V3.5.19.20 | — | cvelist |
| CODESYS Control RTE (SL) | < V3.5.19.20 | — | cvelist |
| CODESYS Control Runtime System Toolkit | < V3.5.19.20 | — | cvelist |
| CODESYS Control Win (SL) | < V3.5.19.20 | — | cvelist |
| CODESYS Development System V3 | < V3.5.19.20 | — | cvelist |
| CODESYS HMI (SL) | < V3.5.19.20 | — | cvelist |
| CODESYS Safety SIL2 Runtime Toolkit | < V3.5.19.20 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-37545. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-37545.md Affected: CODESYS Control for BeagleBone SL < V4.10.0.0; CODESYS Control for emPC-A/iMX6 SL < V4.10.0.0; CODESYS Control for IOT2000 SL < V4.10.0.0; CODESYS Control for Linux SL < V4.10.0.0; CODESYS Control for PFC100 SL < V4.10.0.0; CODESYS Control for PFC200 SL < V4.10.0.0; CODESYS Control for PLCnext SL <… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for CODESYS Control for BeagleBone SL, CODESYS Control for emPC-A/iMX6 SL, CODESYS Control for IOT2000 SL, CODESYS Control for Linux SL, CODESYS Control for PFC100 SL, CODESYS Control for PFC200 SL: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-37545 being exploited?
There is no confirmed exploitation: CVE-2023-37545 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.83% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-37545?
Medium: CVSS 6.5 (v3.1, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2023-37545?
CODESYS Control for BeagleBone SL < V4.10.0.0; CODESYS Control for emPC-A/iMX6 SL < V4.10.0.0; CODESYS Control for IOT2000 SL < V4.10.0.0; CODESYS Control for Linux SL < V4.10.0.0; CODESYS Control for PFC100 SL < V4.10.0.0; CODESYS Control for PFC200 SL < V4.10.0.0; CODESYS Control for PLCnext SL < V4.10.0.0; CODESYS Control for Raspberry Pi SL < V4.10.0.0; CODESYS Control for WAGO Touch Panels 600 SL < V4.10.0.0; CODESYS Control RTE (for Beckhoff CX) SL < V3.5.19.20; CODESYS Control RTE (SL) < V3.5.19.20; CODESYS Control Runtime System Toolkit < V3.5.19.20; CODESYS Control Win (SL) < V3.5.19.20; CODESYS Development System V3 < V3.5.19.20; CODESYS HMI (SL) < V3.5.19.20; CODESYS Safety SIL2 Runtime Toolkit < V3.5.19.20.
Is there a fix for CVE-2023-37545?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2023-37545?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.