# CVE-2023-37482: The login functionality of the web server in affected devices does not normalize the response times of login attempts.…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 6.9
- **CVSS:** 6.9 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: None; Privileges required: None; User interaction: None; Confidentiality impact: Low; Integrity impact: None; Availability impact: None; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.73% (percentile 50, 2026-11-26)
- **CWE:** CWE-203
- **Published:** 2025-02-11T10:26:27.720Z
- **Modified:** 2026-06-17T06:08:18.503Z

## Who should check

- Anyone running Siemens SIMATIC Drive Controller CPU 1504D TF \>= V3.1.0, \< V3.1.2
- Anyone running Siemens SIMATIC Drive Controller CPU 1507D TF \>= V3.1.0, \< V3.1.2
- Anyone running Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN \>= V3.1.0, \< V3.1.2
- Anyone running Siemens SIMATIC ET 200SP CPU 1510SP-1 PN \>= V3.1.0, \< V3.1.2
- Anyone running Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN \>= V3.1.0, \< V3.1.2
- Anyone running Siemens SIMATIC ET 200SP CPU 1512SP-1 PN \>= V3.1.0, \< V3.1.2
- Anyone running Siemens SIMATIC ET 200SP CPU 1514SP F-2 PN \>= V3.1.0, \< V3.1.2
- Anyone running Siemens SIMATIC ET 200SP CPU 1514SP-2 PN \>= V3.1.0, \< V3.1.2

## Description

The login functionality of the web server in affected devices does not normalize the response times of login attempts. An unauthenticated remote attacker could exploit this side-channel information to distinguish between valid and invalid usernames.

## Affected and fixed versions

- Siemens SIMATIC Drive Controller CPU 1504D TF: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC Drive Controller CPU 1507D TF: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1510SP-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1512SP-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1514SP F-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1514SP-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1514SPT F-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP CPU 1514SPT-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1211C AC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1211C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1211C DC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1212C AC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1212C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1212C DC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1214C AC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1214C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1214C DC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1215C AC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1215C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1215C DC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/Rly: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1200 CPU 1217C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1511-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1511C-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1511F-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1511T-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1511TF-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1512C-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1513-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1513F-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1513pro F-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1513pro-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1513R-1 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1515-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1515F-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1515R-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1515T-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1515TF-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1516pro F-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1516pro-2 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1517H-3 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518HF-4 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIMATIC S7-1500 Software Controller CPU 1507S F V3: \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-1500 Software Controller CPU 1507S V3: \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-1500 Software Controller CPU 1508S F V3: \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-1500 Software Controller CPU 1508S T V3: \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-1500 Software Controller CPU 1508S TF V3: \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-1500 Software Controller CPU 1508S V3: \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-1500 Software Controller Linux V3: \>= V30.1.0, \< V31.1.4 (cvelist)
- Siemens SIMATIC S7-PLCSIM Advanced: \>= V6.0, \< V7.0 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215C DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1200 CPU 1215FC DC/DC/DC: \< V4.7 (cvelist)
- Siemens SIPLUS S7-1500 CPU 1517H-3 PN: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP: \>= V3.1.0, \< V3.1.2 (cvelist)
- Siemens SIPLUS S7-1500 CPU 1518HF-4 PN: \>= V3.1.0, \< V3.1.2 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2023-37482. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-37482.md
Affected: Siemens SIMATIC Drive Controller CPU 1504D TF >= V3.1.0, < V3.1.2; Siemens SIMATIC Drive Controller CPU 1507D TF >= V3.1.0, < V3.1.2; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN >= V3.1.0, < V3.1.2; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN >= V3.1.0, < V3.1.2; Siemens SIMATIC ET 200SP CPU 1512SP F-1…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMATIC Drive Controller CPU 1504D TF, Siemens SIMATIC Drive Controller CPU 1507D TF, Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN, Siemens SIMATIC ET 200SP CPU 1510SP-1 PN, Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN, Siemens SIMATIC ET 200SP CPU 1512SP-1 PN: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2023-37482 being exploited?

There is no confirmed exploitation: CVE-2023-37482 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.73% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2023-37482?

Medium: CVSS 6.9 (v4.0, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2023-37482?

Siemens SIMATIC Drive Controller CPU 1504D TF \>= V3.1.0, \< V3.1.2; Siemens SIMATIC Drive Controller CPU 1507D TF \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1512SP-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1514SP F-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1514SP-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1514SPT F-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP CPU 1514SPT-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-1200 CPU 1211C AC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1211C DC/DC/DC \< V4.7; Siemens SIMATIC S7-1200 CPU 1211C DC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1212C AC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1212C DC/DC/DC \< V4.7; Siemens SIMATIC S7-1200 CPU 1212C DC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/DC \< V4.7; Siemens SIMATIC S7-1200 CPU 1212FC DC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1214C AC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1214C DC/DC/DC \< V4.7; Siemens SIMATIC S7-1200 CPU 1214C DC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/DC \< V4.7; Siemens SIMATIC S7-1200 CPU 1214FC DC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1215C AC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1215C DC/DC/DC \< V4.7; Siemens SIMATIC S7-1200 CPU 1215C DC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/DC \< V4.7; Siemens SIMATIC S7-1200 CPU 1215FC DC/DC/Rly \< V4.7; Siemens SIMATIC S7-1200 CPU 1217C DC/DC/DC \< V4.7; Siemens SIMATIC S7-1500 CPU 1511-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1511C-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1511F-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1511T-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1511TF-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1512C-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1513-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1513F-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1513pro F-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1513pro-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1513R-1 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1515-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1515F-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1515R-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1515T-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1515TF-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1516pro F-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1516pro-2 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1517H-3 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518HF-4 PN \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIMATIC S7-1500 Software Controller CPU 1507S F V3 \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-1500 Software Controller CPU 1507S V3 \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-1500 Software Controller CPU 1508S F V3 \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-1500 Software Controller CPU 1508S T V3 \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-1500 Software Controller CPU 1508S TF V3 \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-1500 Software Controller CPU 1508S V3 \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-1500 Software Controller Linux V3 \>= V30.1.0, \< V31.1.4; Siemens SIMATIC S7-PLCSIM Advanced \>= V6.0, \< V7.0; Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1212 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1212 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1214 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL \< V4.7; Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1214FC DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 AC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1215 DC/DC/RLY \< V4.7; Siemens SIPLUS S7-1200 CPU 1215C DC/DC/DC \< V4.7; Siemens SIPLUS S7-1200 CPU 1215FC DC/DC/DC \< V4.7; Siemens SIPLUS S7-1500 CPU 1517H-3 PN \>= V3.1.0, \< V3.1.2; Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP \>= V3.1.0, \< V3.1.2; Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP \>= V3.1.0, \< V3.1.2; Siemens SIPLUS S7-1500 CPU 1518HF-4 PN \>= V3.1.0, \< V3.1.2.

### Is there a fix for CVE-2023-37482?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2023-37482?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert-portal.siemens.com/productcert/html/ssa-195895.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2023-37482>

HTML: <https://flawdb.com/CVE-2023-37482> · JSON: <https://flawdb.com/api/v1/entries/CVE-2023-37482>