CVE-2023-33220
Stack Buffer Overflow when checking some attributes during retrofit
Mitigation
- Upgrade SIGMA Lite & Lite + to 4.15.5 or later.
- Upgrade SIGMA Wide to 4.15.5 or later.
- Upgrade SIGMA Extreme to 4.15.5 or later.
- Upgrade MorphoWave Compact/XP to 2.12.2 or later.
- Upgrade VisionPass to 2.12.2 or later.
- Upgrade MorphoWave SP to 1.2.7 or later.
Who should check
- Anyone running IDEMIA SIGMA Lite & Lite + < 4.15.5
- Anyone running IDEMIA SIGMA Wide < 4.15.5
- Anyone running IDEMIA SIGMA Extreme < 4.15.5
- Anyone running IDEMIA MorphoWave Compact/XP < 2.12.2
- Anyone running IDEMIA VisionPass < 2.12.2
- Anyone running IDEMIA MorphoWave SP < 1.2.7
Vulnerability facts
- Affected
- IDEMIA SIGMA Lite & Lite + < 4.15.5; IDEMIA SIGMA Wide < 4.15.5; IDEMIA SIGMA Extreme < 4.15.5; IDEMIA MorphoWave Compact/XP < 2.12.2; IDEMIA VisionPass < 2.12.2; IDEMIA MorphoWave SP < 1.2.7
- Fixed in
- IDEMIA SIGMA Lite & Lite + 4.15.5, IDEMIA SIGMA Wide 4.15.5, IDEMIA SIGMA Extreme 4.15.5, IDEMIA MorphoWave Compact/XP 2.12.2, IDEMIA VisionPass 2.12.2, IDEMIA MorphoWave SP 1.2.7
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: None
- EPSS
- 1.27% chance of exploitation in 30 days (percentile 70, 2026-11-26)
- CWE
- CWE-121
- Modified
Description
During the retrofit validation process, the firmware doesn't properly check the boundaries while copying some attributes to check. This allows a stack-based buffer overflow that could lead to a potential Remote Code Execution on the targeted device
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-33220. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-33220.md Affected: IDEMIA SIGMA Lite & Lite + < 4.15.5; IDEMIA SIGMA Wide < 4.15.5; IDEMIA SIGMA Extreme < 4.15.5; IDEMIA MorphoWave Compact/XP < 2.12.2; IDEMIA VisionPass < 2.12.2; IDEMIA MorphoWave SP < 1.2.7 Fixed in: IDEMIA SIGMA Lite & Lite + 4.15.5, IDEMIA SIGMA Wide 4.15.5, IDEMIA SIGMA Extreme 4.15.5, IDEMIA MorphoWave Compact/XP 2.12.2, IDEMIA VisionPass 2.12.2, IDEMIA MorphoWave SP 1.2.7 Steps: 1. Search this machine and project for IDEMIA SIGMA Lite & Lite +, IDEMIA SIGMA Wide, IDEMIA SIGMA Extreme, IDEMIA MorphoWave Compact/XP, IDEMIA VisionPass, IDEMIA MorphoWave SP: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-33220 being exploited?
There is no confirmed exploitation: CVE-2023-33220 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.27% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-33220?
Critical: CVSS 9.1 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2023-33220?
IDEMIA SIGMA Lite & Lite + < 4.15.5; IDEMIA SIGMA Wide < 4.15.5; IDEMIA SIGMA Extreme < 4.15.5; IDEMIA MorphoWave Compact/XP < 2.12.2; IDEMIA VisionPass < 2.12.2; IDEMIA MorphoWave SP < 1.2.7.
Is there a fix for CVE-2023-33220?
Yes. Fixed in IDEMIA SIGMA Lite & Lite + 4.15.5, IDEMIA SIGMA Wide 4.15.5, IDEMIA SIGMA Extreme 4.15.5, IDEMIA MorphoWave Compact/XP 2.12.2, IDEMIA VisionPass 2.12.2, IDEMIA MorphoWave SP 1.2.7. Upgrade SIGMA Lite & Lite + to 4.15.5 or later. Upgrade SIGMA Wide to 4.15.5 or later. Upgrade SIGMA Extreme to 4.15.5 or later. Upgrade MorphoWave Compact/XP to 2.12.2 or later. Upgrade VisionPass to 2.12.2 or later. Upgrade MorphoWave SP to 1.2.7 or later.
How do I check if I'm affected by CVE-2023-33220?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.