CVE-2023-32737
A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications d…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIMATIC STEP 7 Safety V18 < V18 Update 2
Vulnerability facts
- Affected
- Siemens SIMATIC STEP 7 Safety V18 < V18 Update 2
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 7.0 (v4.0, CNA)CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Attack requirements: None
- Privileges required: High
- User interaction: Passive
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.59% chance of exploitation in 30 days (percentile 42, 2026-11-26)
- CWE
- CWE-502
- Modified
Description
A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens SIMATIC STEP 7 Safety V18 | < V18 Update 2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-32737. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-32737.md Affected: Siemens SIMATIC STEP 7 Safety V18 < V18 Update 2 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIMATIC STEP 7 Safety V18: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-32737 being exploited?
There is no confirmed exploitation: CVE-2023-32737 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.59% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-32737?
High: CVSS 7.0 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2023-32737?
Siemens SIMATIC STEP 7 Safety V18 < V18 Update 2.
Is there a fix for CVE-2023-32737?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2023-32737?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.