CVE-2023-31173
Use of Hard-coded Credentials
Mitigation
- Upgrade SEL-5037 SEL Grid Configurator to 4.5.0.20 or later.
Who should check
- Anyone running Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator < 4.5.0.20
Vulnerability facts
- Affected
- Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator < 4.5.0.20
- Fixed in
- Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator 4.5.0.20
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 7.7 (v3.1, CNA)CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: None
- EPSS
- 0.31% chance of exploitation in 30 days (percentile 16, 2026-11-26)
- CWE
- CWE-798
- Modified
Description
Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator | < 4.5.0.20 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-31173. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-31173.md Affected: Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator < 4.5.0.20 Fixed in: Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator 4.5.0.20 Steps: 1. Search this machine and project for Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2023-31173 being exploited?
There is no confirmed exploitation: CVE-2023-31173 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.31% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-31173?
High: CVSS 7.7 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2023-31173?
Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator < 4.5.0.20.
Is there a fix for CVE-2023-31173?
Yes. Fixed in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator 4.5.0.20. Upgrade SEL-5037 SEL Grid Configurator to 4.5.0.20 or later.
How do I check if I'm affected by CVE-2023-31173?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.