CVE-2023-29410
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same pr…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric InsightHome >= v1.16 Build 004, <= prior
- Anyone running Schneider Electric InsightFacility >= v1.16 Build 004, <= prior
- Anyone running Schneider Electric Conext Gateway >= v1.16 Build 004, <= prior
Vulnerability facts
- Affected
- Schneider Electric InsightHome >= v1.16 Build 004, <= prior; Schneider Electric InsightFacility >= v1.16 Build 004, <= prior; Schneider Electric Conext Gateway >= v1.16 Build 004, <= prior
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 7.2 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.88% chance of exploitation in 30 days (percentile 57, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric InsightHome | >= v1.16 Build 004, <= prior | — | cvelist |
| Schneider Electric InsightFacility | >= v1.16 Build 004, <= prior | — | cvelist |
| Schneider Electric Conext Gateway | >= v1.16 Build 004, <= prior | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-29410. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-29410.md Affected: Schneider Electric InsightHome >= v1.16 Build 004, <= prior; Schneider Electric InsightFacility >= v1.16 Build 004, <= prior; Schneider Electric Conext Gateway >= v1.16 Build 004, <= prior Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric InsightHome, Schneider Electric InsightFacility, Schneider Electric Conext Gateway: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-29410 being exploited?
There is no confirmed exploitation: CVE-2023-29410 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.88% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-29410?
High: CVSS 7.2 (v3.1, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2023-29410?
Schneider Electric InsightHome >= v1.16 Build 004, <= prior; Schneider Electric InsightFacility >= v1.16 Build 004, <= prior; Schneider Electric Conext Gateway >= v1.16 Build 004, <= prior.
Is there a fix for CVE-2023-29410?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2023-29410?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.