Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2023-28713

HIGH 8.1EPSS 39%

Plaintext storage of a password exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Because account informati…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Contec Co., Ltd. CONPROSYS HMI System (CHS) versions prior to 3.5.3

Vulnerability facts

Affected
Contec Co., Ltd. CONPROSYS HMI System (CHS) versions prior to 3.5.3
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
8.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: None
EPSS
0.53% chance of exploitation in 30 days (percentile 39, 2026-11-26)
CWE
CWE-312
Published
Modified

Description

Plaintext storage of a password exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information in the database may be obtained and/or altered by the user.

Affected and fixed versions

Package / productAffectedFixedSource
Contec Co., Ltd. CONPROSYS HMI System (CHS)versions prior to 3.5.3—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2023-28713. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-28713.md
Affected: Contec Co., Ltd. CONPROSYS HMI System (CHS) versions prior to 3.5.3
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Contec Co., Ltd. CONPROSYS HMI System (CHS): dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2023-28713 being exploited?

There is no confirmed exploitation: CVE-2023-28713 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.53% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2023-28713?

High: CVSS 8.1 (v3.1, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2023-28713?

Contec Co., Ltd. CONPROSYS HMI System (CHS) versions prior to 3.5.3.

Is there a fix for CVE-2023-28713?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2023-28713?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors