CVE-2023-27975

HIGH 7.1EPSS 7%

CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Schneider Electric EcoStruxure Control Expert Versions prior to v16.0
  • Anyone running Schneider Electric EcoStruxure Process Expert Versions prior to v2023

Vulnerability facts

Affected
Schneider Electric EcoStruxure Control Expert Versions prior to v16.0; Schneider Electric EcoStruxure Process Expert Versions prior to v2023
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.1 (v3.1, CNA)CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: None
EPSS
0.22% chance of exploitation in 30 days (percentile 7, 2026-11-26)
CWE
CWE-522
Published
Modified

Description

CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.

Affected and fixed versions

Package / productAffectedFixedSource
Schneider Electric EcoStruxure Control ExpertVersions prior to v16.0—cvelist
Schneider Electric EcoStruxure Process ExpertVersions prior to v2023—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2023-27975. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-27975.md
Affected: Schneider Electric EcoStruxure Control Expert Versions prior to v16.0; Schneider Electric EcoStruxure Process Expert Versions prior to v2023
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric EcoStruxure Control Expert, Schneider Electric EcoStruxure Process Expert: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2023-27975 being exploited?

There is no confirmed exploitation: CVE-2023-27975 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.22% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2023-27975?

High: CVSS 7.1 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2023-27975?

Schneider Electric EcoStruxure Control Expert Versions prior to v16.0; Schneider Electric EcoStruxure Process Expert Versions prior to v2023.

Is there a fix for CVE-2023-27975?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2023-27975?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors