Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2023-2637

HIGH 7.3EPSS 13%

Rockwell Automation FactoryTalk System Services Vulnerable To Use Of Hard-Coded Cryptographic Key

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Rockwell Automation FactoryTalk System Services <= 6.20

Vulnerability facts

Affected
Rockwell Automation FactoryTalk System Services <= 6.20
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.3 (v3.1, CNA)CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: Required
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: Low
  • Integrity impact: Low
  • Availability impact: High
EPSS
0.28% chance of exploitation in 30 days (percentile 13, 2026-11-26)
CWE
CWE-321
Published
Modified

Description

Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies.  Hard-coded cryptographic key may lead to privilege escalation.  This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited.

Affected and fixed versions

Package / productAffectedFixedSource
Rockwell Automation FactoryTalk System Services<= 6.20—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2023-2637. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-2637.md
Affected: Rockwell Automation FactoryTalk System Services <= 6.20
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Rockwell Automation FactoryTalk System Services: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2023-2637 being exploited?

There is no confirmed exploitation: CVE-2023-2637 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.28% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2023-2637?

High: CVSS 7.3 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2023-2637?

Rockwell Automation FactoryTalk System Services <= 6.20.

Is there a fix for CVE-2023-2637?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2023-2637?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors