CVE-2023-2187
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events t…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Triangle MicroWorks SCADA Data Gateway 5.01.03
Vulnerability facts
- Affected
- Triangle MicroWorks SCADA Data Gateway 5.01.03
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.3 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Low
- EPSS
- 0.76% chance of exploitation in 30 days (percentile 52, 2026-11-26)
- CWE
- CWE-306
- Modified
Description
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Triangle MicroWorks SCADA Data Gateway | 5.01.03 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-2187. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-2187.md Affected: Triangle MicroWorks SCADA Data Gateway 5.01.03 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Triangle MicroWorks SCADA Data Gateway: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-2187 being exploited?
There is no confirmed exploitation: CVE-2023-2187 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.76% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-2187?
Medium: CVSS 5.3 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2023-2187?
Triangle MicroWorks SCADA Data Gateway 5.01.03.
Is there a fix for CVE-2023-2187?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2023-2187?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.