# CVE-2023-1258: Flow-X disclosure of sensitive information to unauthenticated users

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 5.3
- **CVSS:** 5.3 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: Low; Integrity impact: None; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** Yes (see exploit references)
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 2.46% (percentile 85, 2026-11-26)
- **CWE:** CWE-200
- **Aliases:** EDB-51603
- **Published:** 2023-03-31T07:56:05.133Z
- **Modified:** 2026-06-17T05:27:29.173Z

## Who should check

- Anyone running ABB Flow-X \< 4.0

## Description

Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0.

## Affected and fixed versions

- ABB Flow-X: \< 4.0 (cvelist)

## Mitigation

- Upgrade Flow-X to 4.0 or later.
- Vendor workaround: To minimize the risk of unauthorized access to sensitive information, ABB recommends to only operate
- Flow-X flow computers in secure networks.
- Additionally, ABB recommends that HTTPS is used to communicate with the Flow-X web server. HTTPS
- support has been implemented since version 1.2.2 (available as of June 2016) and is enabled by default
- since version 3.2.0 (available as of September 2020).
- To minimize the risk of exposed security information on one device leading to unauthorized access on
- other devices, ABB recommends that customers change the usernames and passwords that are part of
- the standard application and to use different usernames and password on different devices

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2023-1258. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-1258.md
Affected: ABB Flow-X < 4.0
Fixed in: ABB Flow-X 4.0

Steps:
1. Search this machine and project for ABB Flow-X: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2023-1258 being exploited?

There is no confirmed exploitation: CVE-2023-1258 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 2.46% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2023-1258?

Medium: CVSS 5.3 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2023-1258?

ABB Flow-X \< 4.0.

### Is there a fix for CVE-2023-1258?

Yes. Fixed in ABB Flow-X 4.0. Upgrade Flow-X to 4.0 or later. Vendor workaround: To minimize the risk of unauthorized access to sensitive information, ABB recommends to only operate Flow-X flow computers in secure networks. Additionally, ABB recommends that HTTPS is used to communicate with the Flow-X web server. HTTPS support has been implemented since version 1.2.2 (available as of June 2016) and is enabled by default since version 3.2.0 (available as of September 2020). To minimize the risk of exposed security information on one device leading to unauthorized access on other devices, ABB recommends that customers change the usernames and passwords that are part of the standard application and to use different usernames and password on different devices

### How do I check if I'm affected by CVE-2023-1258?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A9754&LanguageCode=en&DocumentPartId=&Action=Launch>
- exploit: <http://packetstormsecurity.com/files/173610/ABB-FlowX-4.00-Information-Disclosure.html>
- exploit: <https://www.exploit-db.com/exploits/51603>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2023-1258>
- Exploit-DB: Exploit metadata (ID and link only) from the Exploit Database <https://www.exploit-db.com/exploits/51603>

HTML: <https://flawdb.com/CVE-2023-1258> · JSON: <https://flawdb.com/api/v1/entries/CVE-2023-1258>