CVE-2023-0888

MEDIUM 4.9EPSS 54%

Authenticated eval injection in B. Braun Space Battery pack SP with Wi-Fi

Mitigation

  • Vendor workaround: Use secure credentials and keep them secret. Secure your network to prevent outside access to medical devices.

Who should check

  • Anyone running B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092

Vulnerability facts

Affected
B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
4.9 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: High
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: High
  • Availability impact: None
EPSS
0.81% chance of exploitation in 30 days (percentile 54, 2026-11-26)
CWE
CWE-95
Published
Modified

Description

An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks

Affected and fixed versions

Package / productAffectedFixedSource
B. Braun Space Battery Pack SP with Wi-Fi<= 053L000092; <= 054U000092—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2023-0888. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-0888.md
Affected: B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for B. Braun Space Battery Pack SP with Wi-Fi: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2023-0888 being exploited?

There is no confirmed exploitation: CVE-2023-0888 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.81% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2023-0888?

Medium: CVSS 4.9 (v3.1, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2023-0888?

B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092.

Is there a fix for CVE-2023-0888?

No fixed version is listed in the sources yet. Vendor workaround: Use secure credentials and keep them secret. Secure your network to prevent outside access to medical devices.

How do I check if I'm affected by CVE-2023-0888?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors