CVE-2023-0888
Authenticated eval injection in B. Braun Space Battery pack SP with Wi-Fi
Mitigation
- Vendor workaround: Use secure credentials and keep them secret. Secure your network to prevent outside access to medical devices.
Who should check
- Anyone running B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092
Vulnerability facts
- Affected
- B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 4.9 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- EPSS
- 0.81% chance of exploitation in 30 days (percentile 54, 2026-11-26)
- CWE
- CWE-95
- Modified
Description
An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| B. Braun Space Battery Pack SP with Wi-Fi | <= 053L000092; <= 054U000092 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-0888. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-0888.md Affected: B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for B. Braun Space Battery Pack SP with Wi-Fi: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-0888 being exploited?
There is no confirmed exploitation: CVE-2023-0888 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.81% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-0888?
Medium: CVSS 4.9 (v3.1, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2023-0888?
B. Braun Space Battery Pack SP with Wi-Fi <= 053L000092; <= 054U000092.
Is there a fix for CVE-2023-0888?
No fixed version is listed in the sources yet. Vendor workaround: Use secure credentials and keep them secret. Secure your network to prevent outside access to medical devices.
How do I check if I'm affected by CVE-2023-0888?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.