CVE-2023-0863
Authentication to access the AC wallbox via its Bluetooth Low Energy (BLE) channel can be bypassed,
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running ABB Terra AC wallbox (UL40/80A) >= 1.0;0, <= 1.5.5
- Anyone running ABB Terra AC wallbox (UL32A) >= 1.0;0, <= 1.6.5
- Anyone running ABB Terra AC wallbox (CE) (Terra AC MID) >= 1.0;0, <= 1.6.5
- Anyone running ABB Terra AC wallbox (CE) Terra AC Juno CE >= 1.0;0, <= 1.6.5
- Anyone running ABB Terra AC wallbox (CE) Terra AC PTB >= 1.0;0, <= 1.5.25
- Anyone running ABB Terra AC wallbox (CE) Symbiosis >= 1.0;0, <= 1.2.7
- Anyone running ABB Terra AC wallbox (JP) >= 1.0;0, <= 1.6.5
Vulnerability facts
- Affected
- ABB Terra AC wallbox (UL40/80A) >= 1.0;0, <= 1.5.5; ABB Terra AC wallbox (UL32A) >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) (Terra AC MID) >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) Terra AC Juno CE >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) Terra AC PTB >= 1.0;0, <= 1.5.25; ABB Terra AC wallbox (CE) Symbiosis >= 1.0;0, <= 1.2.7; ABB Terra AC wallbox (JP) >= 1.0;0, <= 1.6.5
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.8 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.50% chance of exploitation in 30 days (percentile 36, 2026-11-26)
- CWE
- CWE-287
- Modified
Description
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| ABB Terra AC wallbox (UL40/80A) | >= 1.0;0, <= 1.5.5 | — | cvelist |
| ABB Terra AC wallbox (UL32A) | >= 1.0;0, <= 1.6.5 | — | cvelist |
| ABB Terra AC wallbox (CE) (Terra AC MID) | >= 1.0;0, <= 1.6.5 | — | cvelist |
| ABB Terra AC wallbox (CE) Terra AC Juno CE | >= 1.0;0, <= 1.6.5 | — | cvelist |
| ABB Terra AC wallbox (CE) Terra AC PTB | >= 1.0;0, <= 1.5.25 | — | cvelist |
| ABB Terra AC wallbox (CE) Symbiosis | >= 1.0;0, <= 1.2.7 | — | cvelist |
| ABB Terra AC wallbox (JP) | >= 1.0;0, <= 1.6.5 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2023-0863. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2023-0863.md Affected: ABB Terra AC wallbox (UL40/80A) >= 1.0;0, <= 1.5.5; ABB Terra AC wallbox (UL32A) >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) (Terra AC MID) >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) Terra AC Juno CE >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) Terra AC PTB >= 1.0;0, <= 1.5.25; ABB Terra AC w… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2023-0863 being exploited?
There is no confirmed exploitation: CVE-2023-0863 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.50% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2023-0863?
High: CVSS 8.8 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2023-0863?
ABB Terra AC wallbox (UL40/80A) >= 1.0;0, <= 1.5.5; ABB Terra AC wallbox (UL32A) >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) (Terra AC MID) >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) Terra AC Juno CE >= 1.0;0, <= 1.6.5; ABB Terra AC wallbox (CE) Terra AC PTB >= 1.0;0, <= 1.5.25; ABB Terra AC wallbox (CE) Symbiosis >= 1.0;0, <= 1.2.7; ABB Terra AC wallbox (JP) >= 1.0;0, <= 1.6.5.
Is there a fix for CVE-2023-0863?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2023-0863?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.