# CVE-2023-0444: A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'Us…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.8
- **CVSS:** 8.8 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: Low; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, login needed
- **EPSS:** 0.88% (percentile 57, 2026-11-26)
- **Published:** 2023-01-24T00:00:00.000Z
- **Modified:** 2026-06-17T05:25:33.987Z

## Who should check

- Anyone running Delta Electronics InfraSuite Device Master 00.00.02a Delta Electronics InfraSuite Device Master 00.00.02a

## Description

A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.

## Affected and fixed versions

- Delta Electronics InfraSuite Device Master 00.00.02a: Delta Electronics InfraSuite Device Master 00.00.02a (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2023-0444. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-0444.md
Affected: Delta Electronics InfraSuite Device Master 00.00.02a Delta Electronics InfraSuite Device Master 00.00.02a
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Delta Electronics InfraSuite Device Master 00.00.02a: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2023-0444 being exploited?

There is no confirmed exploitation: CVE-2023-0444 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.88% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2023-0444?

High: CVSS 8.8 (v3.1, scored by CNA). Remote, login needed.

### Which versions are affected by CVE-2023-0444?

Delta Electronics InfraSuite Device Master 00.00.02a Delta Electronics InfraSuite Device Master 00.00.02a.

### Is there a fix for CVE-2023-0444?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2023-0444?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.tenable.com/security/research/tra-2023-4>