# CVE-2023-0321: Disclosure of Sensitive Information on Campbell Scientific Products

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.1
- **CVSS:** 9.1 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** Yes (see exploit references)
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.86% (percentile 56, 2026-11-26)
- **CWE:** CWE-200
- **Published:** 2023-01-25T00:00:00.000Z
- **Modified:** 2026-06-17T05:25:16.873Z

## Who should check

- Anyone running Campbell Scientific CR6 all version
- Anyone running Campbell Scientific CR300 all version
- Anyone running Campbell Scientific CR800 all version
- Anyone running Campbell Scientific CR1000 all version
- Anyone running Campbell Scientific CR3000 all version

## Description

Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.

## Affected and fixed versions

- Campbell Scientific CR6: all version (cvelist)
- Campbell Scientific CR300: all version (cvelist)
- Campbell Scientific CR800: all version (cvelist)
- Campbell Scientific CR1000: all version (cvelist)
- Campbell Scientific CR3000: all version (cvelist)

## Mitigation

- Vendor workaround: HTTP can be disabled or secured through username/password, and Pakbus can be secured through the use of PakBus encryption key and/or PakBus/TCP password. Campbell Scientific offers a guide with instructions to maximize the security of all Internet connectivity of the affected devices (see more in the references).

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2023-0321. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2023-0321.md
Affected: Campbell Scientific CR6 all version; Campbell Scientific CR300 all version; Campbell Scientific CR800 all version; Campbell Scientific CR1000 all version; Campbell Scientific CR3000 all version
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Campbell Scientific CR6, Campbell Scientific CR300, Campbell Scientific CR800, Campbell Scientific CR1000, Campbell Scientific CR3000: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2023-0321 being exploited?

There is no confirmed exploitation: CVE-2023-0321 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.86% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2023-0321?

Critical: CVSS 9.1 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2023-0321?

Campbell Scientific CR6 all version; Campbell Scientific CR300 all version; Campbell Scientific CR800 all version; Campbell Scientific CR1000 all version; Campbell Scientific CR3000 all version.

### Is there a fix for CVE-2023-0321?

No fixed version is listed in the sources yet. Vendor workaround: HTTP can be disabled or secured through username/password, and Pakbus can be secured through the use of PakBus encryption key and/or PakBus/TCP password. Campbell Scientific offers a guide with instructions to maximize the security of all Internet connectivity of the affected devices (see more in the references).

### How do I check if I'm affected by CVE-2023-0321?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- exploit: <https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html>
- other: <https://www.incibe-cert.es/en/early-warning/ics-advisories/disclosure-sensitive-information-campbell-scientific-products>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2023-0321>

HTML: <https://flawdb.com/CVE-2023-0321> · JSON: <https://flawdb.com/api/v1/entries/CVE-2023-0321>
