CVE-2022-48174
There is a stack overflow vulnerability in ash.c:6030 in busybox before 1.35. In the environment of Internet of Vehicle…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running n/a (versions: see the vendor advisory)
- Anyone running Siemens RUGGEDCOM RST2428P < V3.3
- Anyone running Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3
- Anyone running Siemens SCALANCE XCH328 < V3.3
- Anyone running Siemens SCALANCE XCM324 < V3.3
- Anyone running Siemens SCALANCE XCM328 < V3.3
- Anyone running Siemens SCALANCE XCM332 < V3.3
- Anyone running Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.3
Vulnerability facts
- Affected
- n/a; Siemens RUGGEDCOM RST2428P < V3.3; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3; Siemens SCALANCE XCH328 < V3.3; Siemens SCALANCE XCM324 < V3.3; Siemens SCALANCE XCM328 < V3.3; Siemens SCALANCE XCM332 < V3.3; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SIDIS Secured SmartPlug < V7.26.0310
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.8 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 3.02% chance of exploitation in 30 days (percentile 88, 2026-11-26)
- CWE
- CWE-787
- Modified
Description
There is a stack overflow vulnerability in ash.c:6030 in busybox before 1.35. In the environment of Internet of Vehicles, this vulnerability can be executed from command to arbitrary code execution.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| n/a | — | — | nvd |
| Siemens RUGGEDCOM RST2428P | < V3.3 | — | nvd |
| Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family | < V3.3 | — | nvd |
| Siemens SCALANCE XCH328 | < V3.3 | — | nvd |
| Siemens SCALANCE XCM324 | < V3.3 | — | nvd |
| Siemens SCALANCE XCM328 | < V3.3 | — | nvd |
| Siemens SCALANCE XCM332 | < V3.3 | — | nvd |
| Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (230 V AC, 12xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (230 V AC, 8xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (24 V DC, 12xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (24 V DC, 8xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) | < V3.3 | — | nvd |
| Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) | < V3.3 | — | nvd |
| Siemens SIDIS Secured SmartPlug | < V7.26.0310 | — | nvd |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-48174. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-48174.md Affected: n/a; Siemens RUGGEDCOM RST2428P < V3.3; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3; Siemens SCALANCE XCH328 < V3.3; Siemens SCALANCE XCM324 < V3.3; Siemens SCALANCE XCM328 < V3.3; Siemens SCALANCE XCM332 < V3.3; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.3; Siemens SC… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for n/a, Siemens RUGGEDCOM RST2428P, Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family, Siemens SCALANCE XCH328, Siemens SCALANCE XCM324, Siemens SCALANCE XCM328: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2022-48174 being exploited?
There is no confirmed exploitation: CVE-2022-48174 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 3.02% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-48174?
Critical: CVSS 9.8 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2022-48174?
n/a; Siemens RUGGEDCOM RST2428P < V3.3; Siemens SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family < V3.3; Siemens SCALANCE XCH328 < V3.3; Siemens SCALANCE XCM324 < V3.3; Siemens SCALANCE XCM328 < V3.3; Siemens SCALANCE XCM332 < V3.3; Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (24 V DC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) < V3.3; Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) < V3.3; Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) < V3.3; Siemens SIDIS Secured SmartPlug < V7.26.0310.
Is there a fix for CVE-2022-48174?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-48174?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.