CVE-2022-4616

HIGH 7.2EPSS 92%

The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to command injection through the network diagnosis…

Mitigation

  • Upgrade 4G Router DX-3021 to 1.24 or later.

Who should check

  • Anyone running Delta Industrial Automation 4G Router DX-3021 < 1.24

Vulnerability facts

Affected
Delta Industrial Automation 4G Router DX-3021 < 1.24
Fixed in
Delta Industrial Automation 4G Router DX-3021 1.24
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
7.2 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: High
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
4.46% chance of exploitation in 30 days (percentile 92, 2026-11-26)
CWE
CWE-77
Published
Modified

Description

The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to command injection through the network diagnosis page. This vulnerability could allow a remote unauthenticated user to add files, delete files, and change file permissions.

Affected and fixed versions

Package / productAffectedFixedSource
Delta Industrial Automation 4G Router DX-3021< 1.24—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-4616. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-4616.md
Affected: Delta Industrial Automation 4G Router DX-3021 < 1.24
Fixed in: Delta Industrial Automation 4G Router DX-3021 1.24

Steps:
1. Search this machine and project for Delta Industrial Automation 4G Router DX-3021: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-4616 being exploited?

There is no confirmed exploitation: CVE-2022-4616 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 4.46% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-4616?

High: CVSS 7.2 (v3.1, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2022-4616?

Delta Industrial Automation 4G Router DX-3021 < 1.24.

Is there a fix for CVE-2022-4616?

Yes. Fixed in Delta Industrial Automation 4G Router DX-3021 1.24. Upgrade 4G Router DX-3021 to 1.24 or later.

How do I check if I'm affected by CVE-2022-4616?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors