# CVE-2022-46144: A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \< V2.3), SCALANCE SC622-2C…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.1
- **CVSS:** 7.1 (v4.0, CNA) `CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Attack requirements: None; Privileges required: Low; User interaction: None; Confidentiality impact: None; Integrity impact: None; Availability impact: High; Confidentiality impact on other systems: None; Integrity impact on other systems: None; Availability impact on other systems: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, login needed
- **EPSS:** 1.02% (percentile 62, 2026-11-26)
- **CWE:** CWE-664
- **Published:** 2022-12-13T00:00:00.000Z
- **Modified:** 2026-06-17T05:11:17.670Z

## Who should check

- Anyone running Siemens SCALANCE SC622-2C \< V2.3
- Anyone running Siemens SCALANCE SC622-2C \>= V2.3, \< V3.0
- Anyone running Siemens SCALANCE SC626-2C \< V2.3
- Anyone running Siemens SCALANCE SC626-2C \>= V2.3, \< V3.0
- Anyone running Siemens SCALANCE SC632-2C \< V2.3
- Anyone running Siemens SCALANCE SC632-2C \>= V2.3, \< V3.0
- Anyone running Siemens SCALANCE SC636-2C \< V2.3
- Anyone running Siemens SCALANCE SC636-2C \>= V2.3, \< V3.0

## Description

A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \< V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \>= V2.3 \< V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \< V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \>= V2.3 \< V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \< V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \>= V2.3 \< V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \< V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \>= V2.3 \< V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \< V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \>= V2.3 \< V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \< V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \>= V2.3 \< V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \< V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \< V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \< V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \< V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \< V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \< V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \< V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \< V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \< V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial  interface irresponsive.

## Affected and fixed versions

- Siemens SCALANCE SC622-2C: \< V2.3 (cvelist)
- Siemens SCALANCE SC622-2C: \>= V2.3, \< V3.0 (cvelist)
- Siemens SCALANCE SC626-2C: \< V2.3 (cvelist)
- Siemens SCALANCE SC626-2C: \>= V2.3, \< V3.0 (cvelist)
- Siemens SCALANCE SC632-2C: \< V2.3 (cvelist)
- Siemens SCALANCE SC632-2C: \>= V2.3, \< V3.0 (cvelist)
- Siemens SCALANCE SC636-2C: \< V2.3 (cvelist)
- Siemens SCALANCE SC636-2C: \>= V2.3, \< V3.0 (cvelist)
- Siemens SCALANCE SC642-2C: \< V2.3 (cvelist)
- Siemens SCALANCE SC642-2C: \>= V2.3, \< V3.0 (cvelist)
- Siemens SCALANCE SC646-2C: \< V2.3 (cvelist)
- Siemens SCALANCE SC646-2C: \>= V2.3, \< V3.0 (cvelist)
- Siemens SCALANCE WAM763-1: \< V2.0.0 (cvelist)
- Siemens SCALANCE WAM766-1: \< V2.0.0 (cvelist)
- Siemens SCALANCE WAM766-1 (US): \< V2.0.0 (cvelist)
- Siemens SCALANCE WAM766-1 EEC: \< V2.0.0 (cvelist)
- Siemens SCALANCE WAM766-1 EEC (US): \< V2.0.0 (cvelist)
- Siemens SCALANCE WUM763-1: \< V2.0.0 (cvelist)
- Siemens SCALANCE WUM763-1: \< V2.0.0 (cvelist)
- Siemens SCALANCE WUM766-1: \< V2.0.0 (cvelist)
- Siemens SCALANCE WUM766-1 (USA): \< V2.0.0 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2022-46144. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-46144.md
Affected: Siemens SCALANCE SC622-2C < V2.3; Siemens SCALANCE SC622-2C >= V2.3, < V3.0; Siemens SCALANCE SC626-2C < V2.3; Siemens SCALANCE SC626-2C >= V2.3, < V3.0; Siemens SCALANCE SC632-2C < V2.3; Siemens SCALANCE SC632-2C >= V2.3, < V3.0; Siemens SCALANCE SC636-2C < V2.3; Siemens SCALANCE SC636-2C >= V2.3,…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SCALANCE SC622-2C, Siemens SCALANCE SC626-2C, Siemens SCALANCE SC632-2C, Siemens SCALANCE SC636-2C, Siemens SCALANCE SC642-2C, Siemens SCALANCE SC646-2C: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2022-46144 being exploited?

There is no confirmed exploitation: CVE-2022-46144 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.02% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2022-46144?

High: CVSS 7.1 (v4.0, scored by CNA). Remote, login needed.

### Which versions are affected by CVE-2022-46144?

Siemens SCALANCE SC622-2C \< V2.3; Siemens SCALANCE SC622-2C \>= V2.3, \< V3.0; Siemens SCALANCE SC626-2C \< V2.3; Siemens SCALANCE SC626-2C \>= V2.3, \< V3.0; Siemens SCALANCE SC632-2C \< V2.3; Siemens SCALANCE SC632-2C \>= V2.3, \< V3.0; Siemens SCALANCE SC636-2C \< V2.3; Siemens SCALANCE SC636-2C \>= V2.3, \< V3.0; Siemens SCALANCE SC642-2C \< V2.3; Siemens SCALANCE SC642-2C \>= V2.3, \< V3.0; Siemens SCALANCE SC646-2C \< V2.3; Siemens SCALANCE SC646-2C \>= V2.3, \< V3.0; Siemens SCALANCE WAM763-1 \< V2.0.0; Siemens SCALANCE WAM766-1 \< V2.0.0; Siemens SCALANCE WAM766-1 (US) \< V2.0.0; Siemens SCALANCE WAM766-1 EEC \< V2.0.0; Siemens SCALANCE WAM766-1 EEC (US) \< V2.0.0; Siemens SCALANCE WUM763-1 \< V2.0.0; Siemens SCALANCE WUM763-1 \< V2.0.0; Siemens SCALANCE WUM766-1 \< V2.0.0; Siemens SCALANCE WUM766-1 (USA) \< V2.0.0.

### Is there a fix for CVE-2022-46144?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2022-46144?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- patch: <https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf>
- other: <https://cert-portal.siemens.com/productcert/html/ssa-413565.html>
- other: <https://cert-portal.siemens.com/productcert/html/ssa-690517.html>