CVE-2022-46141
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vuln…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIMATIC STEP 7 (TIA Portal) All versions < V19
Vulnerability facts
- Affected
- Siemens SIMATIC STEP 7 (TIA Portal) All versions < V19
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 4.2 (v3.1, CNA)CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:COpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: High
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- E: P
- RL: O
- RC: C
- EPSS
- 0.16% chance of exploitation in 30 days (percentile 3, 2026-11-26)
- CWE
- CWE-316
- Modified
Description
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens SIMATIC STEP 7 (TIA Portal) | All versions < V19 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-46141. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-46141.md Affected: Siemens SIMATIC STEP 7 (TIA Portal) All versions < V19 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIMATIC STEP 7 (TIA Portal): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2022-46141 being exploited?
There is no confirmed exploitation: CVE-2022-46141 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.16% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-46141?
Medium: CVSS 4.2 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2022-46141?
Siemens SIMATIC STEP 7 (TIA Portal) All versions < V19.
Is there a fix for CVE-2022-46141?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-46141?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.