CVE-2022-45789
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modb…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric EcoStruxure Control Expert All Versions
- Anyone running Schneider Electric EcoStruxure Process Expert All Versions
- Anyone running Schneider Electric Modicon M340 CPU (part numbers BMXP34*) All Versions
- Anyone running Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*) All Versions
- Anyone running Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) All Versions
Vulnerability facts
- Affected
- Schneider Electric EcoStruxure Control Expert All Versions; Schneider Electric EcoStruxure Process Expert All Versions; Schneider Electric Modicon M340 CPU (part numbers BMXP34*) All Versions; Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*) All Versions; Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) All Versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: High
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 1.10% chance of exploitation in 30 days (percentile 65, 2026-11-26)
- CWE
- CWE-294
- Modified
Description
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric EcoStruxure Control Expert | All Versions | — | cvelist |
| Schneider Electric EcoStruxure Process Expert | All Versions | — | cvelist |
| Schneider Electric Modicon M340 CPU (part numbers BMXP34*) | All Versions | — | cvelist |
| Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*) | All Versions | — | cvelist |
| Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) | All Versions | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-45789. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-45789.md Affected: Schneider Electric EcoStruxure Control Expert All Versions; Schneider Electric EcoStruxure Process Expert All Versions; Schneider Electric Modicon M340 CPU (part numbers BMXP34*) All Versions; Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*) All Versions; Schneider Electric Modico… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric EcoStruxure Control Expert, Schneider Electric EcoStruxure Process Expert, Schneider Electric Modicon M340 CPU (part numbers BMXP34*), Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*), Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*…: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-45789 being exploited?
There is no confirmed exploitation: CVE-2022-45789 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.10% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-45789?
High: CVSS 8.1 (v3.1, scored by CNA). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2022-45789?
Schneider Electric EcoStruxure Control Expert All Versions; Schneider Electric EcoStruxure Process Expert All Versions; Schneider Electric Modicon M340 CPU (part numbers BMXP34*) All Versions; Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*) All Versions; Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) All Versions.
Is there a fix for CVE-2022-45789?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-45789?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.