CVE-2022-42784
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens LOGO! 12/24RCE >= V8.3, < *
- Anyone running Siemens LOGO! 12/24RCEo >= V8.3, < *
- Anyone running Siemens LOGO! 230RCE >= V8.3, < *
- Anyone running Siemens LOGO! 230RCEo >= V8.3, < *
- Anyone running Siemens LOGO! 24CE >= V8.3, < *
- Anyone running Siemens LOGO! 24CEo >= V8.3, < *
- Anyone running Siemens LOGO! 24RCE >= V8.3, < *
- Anyone running Siemens LOGO! 24RCEo >= V8.3, < *
Vulnerability facts
- Affected
- Siemens LOGO! 12/24RCE >= V8.3, < *; Siemens LOGO! 12/24RCEo >= V8.3, < *; Siemens LOGO! 230RCE >= V8.3, < *; Siemens LOGO! 230RCEo >= V8.3, < *; Siemens LOGO! 24CE >= V8.3, < *; Siemens LOGO! 24CEo >= V8.3, < *; Siemens LOGO! 24RCE >= V8.3, < *; Siemens LOGO! 24RCEo >= V8.3, < *; Siemens SIPLUS LOGO! 12/24RCE >= V8.3, < *; Siemens SIPLUS LOGO! 12/24RCEo >= V8.3, < *; Siemens SIPLUS LOGO! 230RCE >= V8.3, < *; Siemens SIPLUS LOGO! 230RCEo >= V8.3, < *; Siemens SIPLUS LOGO! 24CE >= V8.3, < *; Siemens SIPLUS LOGO! 24CEo >= V8.3, < *; Siemens SIPLUS LOGO! 24RCE >= V8.3, < *; Siemens SIPLUS LOGO! 24RCEo >= V8.3, < *
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 7.6 (v3.1, CNA)CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:COpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Physical
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Changed (impact reaches other components)
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- E: P
- RL: O
- RC: C
- EPSS
- 0.29% chance of exploitation in 30 days (percentile 14, 2026-11-26)
- CWE
- CWE-1319
- Modified
Description
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens LOGO! 12/24RCE | >= V8.3, < * | — | cvelist |
| Siemens LOGO! 12/24RCEo | >= V8.3, < * | — | cvelist |
| Siemens LOGO! 230RCE | >= V8.3, < * | — | cvelist |
| Siemens LOGO! 230RCEo | >= V8.3, < * | — | cvelist |
| Siemens LOGO! 24CE | >= V8.3, < * | — | cvelist |
| Siemens LOGO! 24CEo | >= V8.3, < * | — | cvelist |
| Siemens LOGO! 24RCE | >= V8.3, < * | — | cvelist |
| Siemens LOGO! 24RCEo | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 12/24RCE | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 12/24RCEo | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 230RCE | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 230RCEo | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 24CE | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 24CEo | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 24RCE | >= V8.3, < * | — | cvelist |
| Siemens SIPLUS LOGO! 24RCEo | >= V8.3, < * | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-42784. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-42784.md Affected: Siemens LOGO! 12/24RCE >= V8.3, < *; Siemens LOGO! 12/24RCEo >= V8.3, < *; Siemens LOGO! 230RCE >= V8.3, < *; Siemens LOGO! 230RCEo >= V8.3, < *; Siemens LOGO! 24CE >= V8.3, < *; Siemens LOGO! 24CEo >= V8.3, < *; Siemens LOGO! 24RCE >= V8.3, < *; Siemens LOGO! 24RCEo >= V8.3, < *; Siemens SIPLUS LO… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens LOGO! 12/24RCE, Siemens LOGO! 12/24RCEo, Siemens LOGO! 230RCE, Siemens LOGO! 230RCEo, Siemens LOGO! 24CE, Siemens LOGO! 24CEo: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2022-42784 being exploited?
There is no confirmed exploitation: CVE-2022-42784 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.29% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-42784?
High: CVSS 7.6 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2022-42784?
Siemens LOGO! 12/24RCE >= V8.3, < *; Siemens LOGO! 12/24RCEo >= V8.3, < *; Siemens LOGO! 230RCE >= V8.3, < *; Siemens LOGO! 230RCEo >= V8.3, < *; Siemens LOGO! 24CE >= V8.3, < *; Siemens LOGO! 24CEo >= V8.3, < *; Siemens LOGO! 24RCE >= V8.3, < *; Siemens LOGO! 24RCEo >= V8.3, < *; Siemens SIPLUS LOGO! 12/24RCE >= V8.3, < *; Siemens SIPLUS LOGO! 12/24RCEo >= V8.3, < *; Siemens SIPLUS LOGO! 230RCE >= V8.3, < *; Siemens SIPLUS LOGO! 230RCEo >= V8.3, < *; Siemens SIPLUS LOGO! 24CE >= V8.3, < *; Siemens SIPLUS LOGO! 24CEo >= V8.3, < *; Siemens SIPLUS LOGO! 24RCE >= V8.3, < *; Siemens SIPLUS LOGO! 24RCEo >= V8.3, < *.
Is there a fix for CVE-2022-42784?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-42784?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.