Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2022-41648

CRITICAL 9.2EPSS 62%

The HEIDENHAIN Controller TNC 640 NC software Version 340590 07 SP5, is vulnerable to improper authentication in its DN…

Mitigation

  • Vendor workaround: HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk:
  • * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system.
  • * Use zone firewalls to isolate and segment the network of the affected devices.
  • * Ask machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.

Who should check

  • Anyone running HEIDENHAIN Controller TNC 640 NC Software 340590 07 SP5

Vulnerability facts

Affected
HEIDENHAIN Controller TNC 640 NC Software 340590 07 SP5
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.2 (v4.0, CNA)CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: High
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
1.02% chance of exploitation in 30 days (percentile 62, 2026-11-26)
CWE
CWE-1188
Published
Modified

Description

The HEIDENHAIN Controller TNC 640 NC software Version 340590 07 SP5, is vulnerable to improper authentication in its DNC communication for CNC machines. Authentication is not enabled by default for DNC communication. This vulnerability may allow an attacker to deny service on the production line, steal sensitive data from the production line, and alter any products created by the production line. Note: CNC machines running the TNC 640 controller require DNC to be enabled for DNC communication to be present.

Affected and fixed versions

Package / productAffectedFixedSource
HEIDENHAIN Controller TNC 640 NC Software340590 07 SP5—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-41648. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-41648.md
Affected: HEIDENHAIN Controller TNC 640 NC Software 340590 07 SP5
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for HEIDENHAIN Controller TNC 640 NC Software: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-41648 being exploited?

There is no confirmed exploitation: CVE-2022-41648 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.02% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-41648?

Critical: CVSS 9.2 (v4.0, scored by CNA). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2022-41648?

HEIDENHAIN Controller TNC 640 NC Software 340590 07 SP5.

Is there a fix for CVE-2022-41648?

No fixed version is listed in the sources yet. Vendor workaround: HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk: * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system. * Use zone firewalls to isolate and segment the network of the affected devices. * Ask machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.

How do I check if I'm affected by CVE-2022-41648?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors