A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V17 Update 4)…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants) All versions < V17 Update 4
  • Anyone running Siemens SIMATIC HMI KTP Mobile Panels All versions < V17 Update 4
  • Anyone running Siemens SIMATIC HMI KTP1200 Basic All versions < V17 Update 5
  • Anyone running Siemens SIMATIC HMI KTP400 Basic All versions < V17 Update 5
  • Anyone running Siemens SIMATIC HMI KTP700 Basic All versions < V17 Update 5
  • Anyone running Siemens SIMATIC HMI KTP900 Basic All versions < V17 Update 5
  • Anyone running Siemens SIPLUS HMI KTP1200 BASIC All versions < V17 Update 5
  • Anyone running Siemens SIPLUS HMI KTP400 BASIC All versions < V17 Update 5

Vulnerability facts

Affected
Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants) All versions < V17 Update 4; Siemens SIMATIC HMI KTP Mobile Panels All versions < V17 Update 4; Siemens SIMATIC HMI KTP1200 Basic All versions < V17 Update 5; Siemens SIMATIC HMI KTP400 Basic All versions < V17 Update 5; Siemens SIMATIC HMI KTP700 Basic All versions < V17 Update 5; Siemens SIMATIC HMI KTP900 Basic All versions < V17 Update 5; Siemens SIPLUS HMI KTP1200 BASIC All versions < V17 Update 5; Siemens SIPLUS HMI KTP400 BASIC All versions < V17 Update 5; Siemens SIPLUS HMI KTP700 BASIC All versions < V17 Update 5; Siemens SIPLUS HMI KTP900 BASIC All versions < V17 Update 5
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
1.23% chance of exploitation in 30 days (percentile 69, 2026-11-26)
CWE
CWE-20
Published
Modified

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V17 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V17 Update 4), SIMATIC HMI KTP1200 Basic (All versions < V17 Update 5), SIMATIC HMI KTP400 Basic (All versions < V17 Update 5), SIMATIC HMI KTP700 Basic (All versions < V17 Update 5), SIMATIC HMI KTP900 Basic (All versions < V17 Update 5), SIPLUS HMI KTP1200 BASIC (All versions < V17 Update 5), SIPLUS HMI KTP400 BASIC (All versions < V17 Update 5), SIPLUS HMI KTP700 BASIC (All versions < V17 Update 5), SIPLUS HMI KTP900 BASIC (All versions < V17 Update 5). Affected devices do not properly validate input sent to certain services over TCP. This could allow an unauthenticated remote attacker to cause a permanent denial of service condition (requiring a device reboot) by sending specially crafted TCP packets.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants)All versions < V17 Update 4—cvelist
Siemens SIMATIC HMI KTP Mobile PanelsAll versions < V17 Update 4—cvelist
Siemens SIMATIC HMI KTP1200 BasicAll versions < V17 Update 5—cvelist
Siemens SIMATIC HMI KTP400 BasicAll versions < V17 Update 5—cvelist
Siemens SIMATIC HMI KTP700 BasicAll versions < V17 Update 5—cvelist
Siemens SIMATIC HMI KTP900 BasicAll versions < V17 Update 5—cvelist
Siemens SIPLUS HMI KTP1200 BASICAll versions < V17 Update 5—cvelist
Siemens SIPLUS HMI KTP400 BASICAll versions < V17 Update 5—cvelist
Siemens SIPLUS HMI KTP700 BASICAll versions < V17 Update 5—cvelist
Siemens SIPLUS HMI KTP900 BASICAll versions < V17 Update 5—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-40227. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-40227.md
Affected: Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants) All versions < V17 Update 4; Siemens SIMATIC HMI KTP Mobile Panels All versions < V17 Update 4; Siemens SIMATIC HMI KTP1200 Basic All versions < V17 Update 5; Siemens SIMATIC HMI KTP400 Basic All versions < V17 Update 5; Siemens SIMATIC HMI…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants), Siemens SIMATIC HMI KTP Mobile Panels, Siemens SIMATIC HMI KTP1200 Basic, Siemens SIMATIC HMI KTP400 Basic, Siemens SIMATIC HMI KTP700 Basic, Siemens SIMATIC HMI KTP900 Basic: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-40227 being exploited?

There is no confirmed exploitation: CVE-2022-40227 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.23% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-40227?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2022-40227?

Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants) All versions < V17 Update 4; Siemens SIMATIC HMI KTP Mobile Panels All versions < V17 Update 4; Siemens SIMATIC HMI KTP1200 Basic All versions < V17 Update 5; Siemens SIMATIC HMI KTP400 Basic All versions < V17 Update 5; Siemens SIMATIC HMI KTP700 Basic All versions < V17 Update 5; Siemens SIMATIC HMI KTP900 Basic All versions < V17 Update 5; Siemens SIPLUS HMI KTP1200 BASIC All versions < V17 Update 5; Siemens SIPLUS HMI KTP400 BASIC All versions < V17 Update 5; Siemens SIPLUS HMI KTP700 BASIC All versions < V17 Update 5; Siemens SIPLUS HMI KTP900 BASIC All versions < V17 Update 5.

Is there a fix for CVE-2022-40227?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2022-40227?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors