A vulnerability has been identified in SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIPLUS TIM 1531 IRC < V2.4.8
- Anyone running Siemens TIM 1531 IRC < V2.4.8
Vulnerability facts
- Affected
- Siemens SIPLUS TIM 1531 IRC < V2.4.8; Siemens TIM 1531 IRC < V2.4.8
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 6.9 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: Low
- User interaction: Passive
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 0.78% chance of exploitation in 30 days (percentile 52, 2026-11-26)
- CWE
- CWE-681
- Modified
Description
A vulnerability has been identified in SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). Casting an internal value could lead to floating point exception under certain circumstances. This could allow an attacker to cause a denial of service condition on affected devices.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-40225. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-40225.md Affected: Siemens SIPLUS TIM 1531 IRC < V2.4.8; Siemens TIM 1531 IRC < V2.4.8 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIPLUS TIM 1531 IRC, Siemens TIM 1531 IRC: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-40225 being exploited?
There is no confirmed exploitation: CVE-2022-40225 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.78% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-40225?
Medium: CVSS 6.9 (v4.0, scored by CNA). Remote, login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2022-40225?
Siemens SIPLUS TIM 1531 IRC < V2.4.8; Siemens TIM 1531 IRC < V2.4.8.
Is there a fix for CVE-2022-40225?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-40225?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.