CVE-2022-39065
A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting ca…
Mitigation
- Upgrade TRÅDFRI gateway system to 1.19.26 or later.
Who should check
- Anyone running Ikea TRÅDFRI gateway system < 1.19.26
Vulnerability facts
- Affected
- Ikea TRÅDFRI gateway system < 1.19.26
- Fixed in
- Ikea TRÅDFRI gateway system 1.19.26
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 6.5 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 0.41% chance of exploitation in 30 days (percentile 27, 2026-11-26)
- CWE
- CWE-241
- Modified
Description
A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Ikea TRÅDFRI gateway system | < 1.19.26 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-39065. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-39065.md Affected: Ikea TRÅDFRI gateway system < 1.19.26 Fixed in: Ikea TRÅDFRI gateway system 1.19.26 Steps: 1. Search this machine and project for Ikea TRÅDFRI gateway system: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-39065 being exploited?
There is no confirmed exploitation: CVE-2022-39065 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.41% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-39065?
Medium: CVSS 6.5 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2022-39065?
Ikea TRÅDFRI gateway system < 1.19.26.
Is there a fix for CVE-2022-39065?
Yes. Fixed in Ikea TRÅDFRI gateway system 1.19.26. Upgrade TRÅDFRI gateway system to 1.19.26 or later.
How do I check if I'm affected by CVE-2022-39065?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.