CVE-2022-38371
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All ve…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens APOGEE MBC (PPC) (BACnet) All versions
- Anyone running Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions
- Anyone running Siemens APOGEE MEC (PPC) (BACnet) All versions
- Anyone running Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions
- Anyone running Siemens APOGEE PXC Compact (BACnet) < V3.5.7
- Anyone running Siemens APOGEE PXC Compact (P2 Ethernet) < V2.8.21
- Anyone running Siemens APOGEE PXC Modular (BACnet) < V3.5.7
- Anyone running Siemens APOGEE PXC Modular (P2 Ethernet) < V2.8.21
Vulnerability facts
- Affected
- Siemens APOGEE MBC (PPC) (BACnet) All versions; Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions; Siemens APOGEE MEC (PPC) (BACnet) All versions; Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions; Siemens APOGEE PXC Compact (BACnet) < V3.5.7; Siemens APOGEE PXC Compact (P2 Ethernet) < V2.8.21; Siemens APOGEE PXC Modular (BACnet) < V3.5.7; Siemens APOGEE PXC Modular (P2 Ethernet) < V2.8.21; Siemens Desigo PXC00-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC00-U >= V2.3, < V6.30.37; Siemens Desigo PXC001-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC100-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC12-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC128-U >= V2.3, < V6.30.37; Siemens Desigo PXC200-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC22-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC22.1-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC36.1-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC50-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC64-U >= V2.3, < V6.30.37; Siemens Desigo PXM20-E >= V2.3, < V6.30.37; Siemens Nucleus NET for Nucleus PLUS V1 All versions < V5.2a; Siemens Nucleus NET for Nucleus PLUS V2 All versions < V5.4; Siemens Nucleus ReadyStart V3 V2012 All versions < V2012.08.1; Siemens Nucleus ReadyStart V3 V2017 All versions < V2017.02.4; Siemens Nucleus Source Code < *; Siemens TALON TC Compact (BACnet) < V3.5.7; Siemens TALON TC Modular (BACnet) < V3.5.7
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Attack requirements: None
- Privileges required: None
- User interaction: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- Confidentiality impact on other systems: None
- Integrity impact on other systems: None
- Availability impact on other systems: None
- EPSS
- 1.45% chance of exploitation in 30 days (percentile 74, 2026-11-26)
- CWE
- CWE-400
- Modified
Description
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens APOGEE MBC (PPC) (BACnet) | All versions | — | cvelist |
| Siemens APOGEE MBC (PPC) (P2 Ethernet) | All versions | — | cvelist |
| Siemens APOGEE MEC (PPC) (BACnet) | All versions | — | cvelist |
| Siemens APOGEE MEC (PPC) (P2 Ethernet) | All versions | — | cvelist |
| Siemens APOGEE PXC Compact (BACnet) | < V3.5.7 | — | cvelist |
| Siemens APOGEE PXC Compact (P2 Ethernet) | < V2.8.21 | — | cvelist |
| Siemens APOGEE PXC Modular (BACnet) | < V3.5.7 | — | cvelist |
| Siemens APOGEE PXC Modular (P2 Ethernet) | < V2.8.21 | — | cvelist |
| Siemens Desigo PXC00-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC00-U | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC001-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC100-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC12-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC128-U | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC200-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC22-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC22.1-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC36.1-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC50-E.D | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXC64-U | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Desigo PXM20-E | >= V2.3, < V6.30.37 | — | cvelist |
| Siemens Nucleus NET for Nucleus PLUS V1 | All versions < V5.2a | — | cvelist |
| Siemens Nucleus NET for Nucleus PLUS V2 | All versions < V5.4 | — | cvelist |
| Siemens Nucleus ReadyStart V3 V2012 | All versions < V2012.08.1 | — | cvelist |
| Siemens Nucleus ReadyStart V3 V2017 | All versions < V2017.02.4 | — | cvelist |
| Siemens Nucleus Source Code | < * | — | cvelist |
| Siemens TALON TC Compact (BACnet) | < V3.5.7 | — | cvelist |
| Siemens TALON TC Modular (BACnet) | < V3.5.7 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-38371. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-38371.md Affected: Siemens APOGEE MBC (PPC) (BACnet) All versions; Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions; Siemens APOGEE MEC (PPC) (BACnet) All versions; Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions; Siemens APOGEE PXC Compact (BACnet) < V3.5.7; Siemens APOGEE PXC Compact (P2 Ethernet) < V2.8.21;… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens APOGEE MBC (PPC) (BACnet), Siemens APOGEE MBC (PPC) (P2 Ethernet), Siemens APOGEE MEC (PPC) (BACnet), Siemens APOGEE MEC (PPC) (P2 Ethernet), Siemens APOGEE PXC Compact (BACnet), Siemens APOGEE PXC Compact (P2 Ethernet): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Patches
FAQ
Is CVE-2022-38371 being exploited?
There is no confirmed exploitation: CVE-2022-38371 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.45% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-38371?
High: CVSS 8.7 (v4.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2022-38371?
Siemens APOGEE MBC (PPC) (BACnet) All versions; Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions; Siemens APOGEE MEC (PPC) (BACnet) All versions; Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions; Siemens APOGEE PXC Compact (BACnet) < V3.5.7; Siemens APOGEE PXC Compact (P2 Ethernet) < V2.8.21; Siemens APOGEE PXC Modular (BACnet) < V3.5.7; Siemens APOGEE PXC Modular (P2 Ethernet) < V2.8.21; Siemens Desigo PXC00-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC00-U >= V2.3, < V6.30.37; Siemens Desigo PXC001-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC100-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC12-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC128-U >= V2.3, < V6.30.37; Siemens Desigo PXC200-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC22-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC22.1-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC36.1-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC50-E.D >= V2.3, < V6.30.37; Siemens Desigo PXC64-U >= V2.3, < V6.30.37; Siemens Desigo PXM20-E >= V2.3, < V6.30.37; Siemens Nucleus NET for Nucleus PLUS V1 All versions < V5.2a; Siemens Nucleus NET for Nucleus PLUS V2 All versions < V5.4; Siemens Nucleus ReadyStart V3 V2012 All versions < V2012.08.1; Siemens Nucleus ReadyStart V3 V2017 All versions < V2017.02.4; Siemens Nucleus Source Code < *; Siemens TALON TC Compact (BACnet) < V3.5.7; Siemens TALON TC Modular (BACnet) < V3.5.7.
Is there a fix for CVE-2022-38371?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-38371?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.