Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2022-37660

MEDIUM 6.5EPSS 47%

In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that su…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running n/a (versions: see the vendor advisory)
  • Anyone running Siemens SIDIS Secured SmartPlug < V7.26.0310

Vulnerability facts

Affected
n/a; Siemens SIDIS Secured SmartPlug < V7.26.0310
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
6.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: Low
  • Integrity impact: Low
  • Availability impact: None
EPSS
0.67% chance of exploitation in 30 days (percentile 47, 2026-11-26)
CWE
CWE-323
Published
Modified

Description

In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that successfully bootstrapped public keys with another entity using PKEX in the past, will be able to subvert a future bootstrapping by passively observing public keys, re-using the encrypting element Qi and subtracting it from the captured message M (X = M - Qi). This will result in the public ephemeral key X; the only element required to subvert the PKEX association.

Affected and fixed versions

Package / productAffectedFixedSource
n/a——nvd
Siemens SIDIS Secured SmartPlug< V7.26.0310—nvd

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-37660. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-37660.md
Affected: n/a; Siemens SIDIS Secured SmartPlug < V7.26.0310
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for n/a, Siemens SIDIS Secured SmartPlug: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-37660 being exploited?

There is no confirmed exploitation: CVE-2022-37660 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.67% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-37660?

Medium: CVSS 6.5 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2022-37660?

n/a; Siemens SIDIS Secured SmartPlug < V7.26.0310.

Is there a fix for CVE-2022-37660?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2022-37660?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors