# CVE-2022-3738: WAGO: Missing authentication for config export functionality in multiple products

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 5.9
- **CVSS:** 5.9 (v3.1, CNA) `CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: High; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: None; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.69% (percentile 48, 2026-11-26)
- **CWE:** CWE-306
- **Published:** 2023-01-19T11:27:51.814Z
- **Modified:** 2026-06-17T05:00:12.340Z

## Who should check

- Anyone running Series WAGO PFC100 \>= FW16, \<= FW22
- Anyone running Series WAGO PFC200 \>= FW16, \<= FW22
- Anyone running Series WAGO Touch Panel 600 Advanced Line \>= FW16, \<= FW22
- Anyone running Series WAGO Touch Panel 600 Marine Line \>= FW16, \<= FW22
- Anyone running Series WAGO Touch Panel 600 Standard Line \>= FW16, \<= FW22
- Anyone running WAGO Compact Controller CC100 \>= FW16, \<= FW22
- Anyone running WAGO Edge Controller \>= FW16, \<= FW22

## Description

The vulnerability allows a remote unauthenticated attacker to download a backup file, if one exists. That backup file might contain sensitive information like credentials and cryptographic material. A valid user has to create a backup after the last reboot for this attack to be successfull.

## Affected and fixed versions

- Series WAGO PFC100: \>= FW16, \<= FW22 (cvelist)
- Series WAGO PFC200: \>= FW16, \<= FW22 (cvelist)
- Series WAGO Touch Panel 600 Advanced Line: \>= FW16, \<= FW22 (cvelist)
- Series WAGO Touch Panel 600 Marine Line: \>= FW16, \<= FW22 (cvelist)
- Series WAGO Touch Panel 600 Standard Line: \>= FW16, \<= FW22 (cvelist)
- WAGO Compact Controller CC100: \>= FW16, \<= FW22 (cvelist)
- WAGO Edge Controller: \>= FW16, \<= FW22 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2022-3738. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-3738.md
Affected: Series WAGO PFC100 >= FW16, <= FW22; Series WAGO PFC200 >= FW16, <= FW22; Series WAGO Touch Panel 600 Advanced Line >= FW16, <= FW22; Series WAGO Touch Panel 600 Marine Line >= FW16, <= FW22; Series WAGO Touch Panel 600 Standard Line >= FW16, <= FW22; WAGO Compact Controller CC100 >= FW16, <= FW22;…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Series WAGO PFC100, Series WAGO PFC200, Series WAGO Touch Panel 600 Advanced Line, Series WAGO Touch Panel 600 Marine Line, Series WAGO Touch Panel 600 Standard Line, WAGO Compact Controller CC100: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2022-3738 being exploited?

There is no confirmed exploitation: CVE-2022-3738 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.69% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2022-3738?

Medium: CVSS 5.9 (v3.1, scored by CNA). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.

### Which versions are affected by CVE-2022-3738?

Series WAGO PFC100 \>= FW16, \<= FW22; Series WAGO PFC200 \>= FW16, \<= FW22; Series WAGO Touch Panel 600 Advanced Line \>= FW16, \<= FW22; Series WAGO Touch Panel 600 Marine Line \>= FW16, \<= FW22; Series WAGO Touch Panel 600 Standard Line \>= FW16, \<= FW22; WAGO Compact Controller CC100 \>= FW16, \<= FW22; WAGO Edge Controller \>= FW16, \<= FW22.

### Is there a fix for CVE-2022-3738?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2022-3738?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert.vde.com/en/advisories/VDE-2022-054/>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2022-3738>

HTML: <https://flawdb.com/CVE-2022-3738> · JSON: <https://flawdb.com/api/v1/entries/CVE-2022-3738>