# CVE-2022-36362: A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD0…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.5
- **CVSS:** 7.5 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High; E: P; RL: T; RC: C
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.08% (percentile 65, 2026-11-26)
- **CWE:** CWE-20
- **Published:** 2022-10-11T00:00:00.000Z
- **Modified:** 2026-06-17T04:53:19.563Z

## Who should check

- Anyone running Siemens LOGO! 12/24RCE All versions
- Anyone running Siemens LOGO! 12/24RCEo All versions
- Anyone running Siemens LOGO! 230RCE All versions
- Anyone running Siemens LOGO! 230RCEo All versions
- Anyone running Siemens LOGO! 24CE All versions
- Anyone running Siemens LOGO! 24CEo All versions
- Anyone running Siemens LOGO! 24RCE All versions
- Anyone running Siemens LOGO! 24RCEo All versions

## Description

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.

## Affected and fixed versions

- Siemens LOGO! 12/24RCE: All versions (cvelist)
- Siemens LOGO! 12/24RCE: All versions (cvelist)
- Siemens LOGO! 12/24RCEo: All versions (cvelist)
- Siemens LOGO! 12/24RCEo: All versions (cvelist)
- Siemens LOGO! 230RCE: All versions (cvelist)
- Siemens LOGO! 230RCE: All versions (cvelist)
- Siemens LOGO! 230RCEo: All versions (cvelist)
- Siemens LOGO! 230RCEo: All versions (cvelist)
- Siemens LOGO! 24CE: All versions (cvelist)
- Siemens LOGO! 24CE: All versions (cvelist)
- Siemens LOGO! 24CEo: All versions (cvelist)
- Siemens LOGO! 24CEo: All versions (cvelist)
- Siemens LOGO! 24RCE: All versions (cvelist)
- Siemens LOGO! 24RCE: All versions (cvelist)
- Siemens LOGO! 24RCEo: All versions (cvelist)
- Siemens LOGO! 24RCEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 12/24RCE: All versions (cvelist)
- Siemens SIPLUS LOGO! 12/24RCE: All versions (cvelist)
- Siemens SIPLUS LOGO! 12/24RCEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 12/24RCEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 230RCE: All versions (cvelist)
- Siemens SIPLUS LOGO! 230RCE: All versions (cvelist)
- Siemens SIPLUS LOGO! 230RCEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 230RCEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 24CE: All versions (cvelist)
- Siemens SIPLUS LOGO! 24CE: All versions (cvelist)
- Siemens SIPLUS LOGO! 24CEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 24CEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 24RCE: All versions (cvelist)
- Siemens SIPLUS LOGO! 24RCE: All versions (cvelist)
- Siemens SIPLUS LOGO! 24RCEo: All versions (cvelist)
- Siemens SIPLUS LOGO! 24RCEo: All versions (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2022-36362. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-36362.md
Affected: Siemens LOGO! 12/24RCE All versions; Siemens LOGO! 12/24RCE All versions; Siemens LOGO! 12/24RCEo All versions; Siemens LOGO! 12/24RCEo All versions; Siemens LOGO! 230RCE All versions; Siemens LOGO! 230RCE All versions; Siemens LOGO! 230RCEo All versions; Siemens LOGO! 230RCEo All versions; Siemens…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens LOGO! 12/24RCE, Siemens LOGO! 12/24RCEo, Siemens LOGO! 230RCE, Siemens LOGO! 230RCEo, Siemens LOGO! 24CE, Siemens LOGO! 24CEo: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2022-36362 being exploited?

There is no confirmed exploitation: CVE-2022-36362 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.08% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2022-36362?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2022-36362?

Siemens LOGO! 12/24RCE All versions; Siemens LOGO! 12/24RCE All versions; Siemens LOGO! 12/24RCEo All versions; Siemens LOGO! 12/24RCEo All versions; Siemens LOGO! 230RCE All versions; Siemens LOGO! 230RCE All versions; Siemens LOGO! 230RCEo All versions; Siemens LOGO! 230RCEo All versions; Siemens LOGO! 24CE All versions; Siemens LOGO! 24CE All versions; Siemens LOGO! 24CEo All versions; Siemens LOGO! 24CEo All versions; Siemens LOGO! 24RCE All versions; Siemens LOGO! 24RCE All versions; Siemens LOGO! 24RCEo All versions; Siemens LOGO! 24RCEo All versions; Siemens SIPLUS LOGO! 12/24RCE All versions; Siemens SIPLUS LOGO! 12/24RCE All versions; Siemens SIPLUS LOGO! 12/24RCEo All versions; Siemens SIPLUS LOGO! 12/24RCEo All versions; Siemens SIPLUS LOGO! 230RCE All versions; Siemens SIPLUS LOGO! 230RCE All versions; Siemens SIPLUS LOGO! 230RCEo All versions; Siemens SIPLUS LOGO! 230RCEo All versions; Siemens SIPLUS LOGO! 24CE All versions; Siemens SIPLUS LOGO! 24CE All versions; Siemens SIPLUS LOGO! 24CEo All versions; Siemens SIPLUS LOGO! 24CEo All versions; Siemens SIPLUS LOGO! 24RCE All versions; Siemens SIPLUS LOGO! 24RCE All versions; Siemens SIPLUS LOGO! 24RCEo All versions; Siemens SIPLUS LOGO! 24RCEo All versions.

### Is there a fix for CVE-2022-36362?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2022-36362?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- patch: <https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf>
- other: <https://cert-portal.siemens.com/productcert/html/ssa-955858.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2022-36362>

HTML: <https://flawdb.com/CVE-2022-36362> · JSON: <https://flawdb.com/api/v1/entries/CVE-2022-36362>