CVE-2022-34823
Buffer overflow vulnerability in CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running NEC Corporation CLUSTERPRO X CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier, CLUSTERPRO X 5.0 SingleServerSafe for Windows and earlier, EXPRESSCLUSTER X 5.0 SingleServerSafe for Windows and earlier
Vulnerability facts
- Affected
- NEC Corporation CLUSTERPRO X CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier, CLUSTERPRO X 5.0 SingleServerSafe for Windows and earlier, EXPRESSCLUSTER X 5.0 SingleServerSafe for Windows and earlier
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.8 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 1.75% chance of exploitation in 30 days (percentile 78, 2026-11-26)
- CWE
- CWE-120
- Modified
Description
Buffer overflow vulnerability in CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier, CLUSTERPRO X 5.0 SingleServerSafe for Windows and earlier, EXPRESSCLUSTER X 5.0 SingleServerSafe for Windows and earlier allows a remote unauthenticated attacker to overwrite existing files on the file system and to potentially execute arbitrary code.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| NEC Corporation CLUSTERPRO X | CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier, CLUSTERPRO X 5.0 SingleServerSafe for Windows and earlier, EXPRESSCLUSTER X 5.0 SingleServerSafe for Windows and earlier | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-34823. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-34823.md Affected: NEC Corporation CLUSTERPRO X CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier, CLUSTERPRO X 5.0 SingleServerSafe for Windows and earlier, EXPRESSCLUSTER X 5.0 SingleServerSafe for Windows and earlier Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for NEC Corporation CLUSTERPRO X: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2022-34823 being exploited?
There is no confirmed exploitation: CVE-2022-34823 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.75% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-34823?
Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2022-34823?
NEC Corporation CLUSTERPRO X CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier, CLUSTERPRO X 5.0 SingleServerSafe for Windows and earlier, EXPRESSCLUSTER X 5.0 SingleServerSafe for Windows and earlier.
Is there a fix for CVE-2022-34823?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-34823?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.