CVE-2022-34821

HIGH 8.8EPSS 85%

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens RUGGEDCOM RM1224 LTE(4G) EU < V7.2
  • Anyone running Siemens RUGGEDCOM RM1224 LTE(4G) NAM < V7.2
  • Anyone running Siemens SCALANCE M804PB < V7.2
  • Anyone running Siemens SCALANCE M812-1 ADSL-Router < V7.2
  • Anyone running Siemens SCALANCE M816-1 ADSL-Router < V7.2
  • Anyone running Siemens SCALANCE M826-2 SHDSL-Router < V7.2
  • Anyone running Siemens SCALANCE M874-2 < V7.2
  • Anyone running Siemens SCALANCE M874-3 < V7.2

Vulnerability facts

Affected
Siemens RUGGEDCOM RM1224 LTE(4G) EU < V7.2; Siemens RUGGEDCOM RM1224 LTE(4G) NAM < V7.2; Siemens SCALANCE M804PB < V7.2; Siemens SCALANCE M812-1 ADSL-Router < V7.2; Siemens SCALANCE M812-1 ADSL-Router < V7.2; Siemens SCALANCE M816-1 ADSL-Router < V7.2; Siemens SCALANCE M816-1 ADSL-Router < V7.2; Siemens SCALANCE M826-2 SHDSL-Router < V7.2; Siemens SCALANCE M874-2 < V7.2; Siemens SCALANCE M874-3 < V7.2; Siemens SCALANCE M876-3 < V7.2; Siemens SCALANCE M876-3 (ROK) < V7.2; Siemens SCALANCE M876-4 < V7.2; Siemens SCALANCE M876-4 (EU) < V7.2; Siemens SCALANCE M876-4 (NAM) < V7.2; Siemens SCALANCE MUM853-1 (EU) < V7.2; Siemens SCALANCE MUM856-1 (EU) < V7.2; Siemens SCALANCE MUM856-1 (RoW) < V7.2; Siemens SCALANCE S615 EEC LAN-Router < V7.2; Siemens SCALANCE S615 LAN-Router < V7.2; Siemens SCALANCE SC622-2C < V2.3; Siemens SCALANCE SC622-2C >= V2.3, < V3.0; Siemens SCALANCE SC626-2C < V2.3; Siemens SCALANCE SC626-2C >= V2.3, < V3.0; Siemens SCALANCE SC632-2C < V2.3; Siemens SCALANCE SC632-2C >= V2.3, < V3.0; Siemens SCALANCE SC636-2C < V2.3; Siemens SCALANCE SC636-2C >= V2.3, < V3.0; Siemens SCALANCE SC642-2C < V2.3; Siemens SCALANCE SC642-2C >= V2.3, < V3.0; Siemens SCALANCE SC646-2C < V2.3; Siemens SCALANCE SC646-2C >= V2.3, < V3.0; Siemens SCALANCE WAB762-1 < V3.0.0; Siemens SCALANCE WAM763-1 < V3.0.0; Siemens SCALANCE WAM763-1 (ME) < V3.0.0; Siemens SCALANCE WAM763-1 (US) < V3.0.0; Siemens SCALANCE WAM766-1 < V3.0.0; Siemens SCALANCE WAM766-1 (ME) < V3.0.0; Siemens SCALANCE WAM766-1 (US) < V3.0.0; Siemens SCALANCE WAM766-1 EEC < V3.0.0; Siemens SCALANCE WAM766-1 EEC (ME) < V3.0.0; Siemens SCALANCE WAM766-1 EEC (US) < V3.0.0; Siemens SCALANCE WUB762-1 < V3.0.0; Siemens SCALANCE WUB762-1 iFeatures < V3.0.0; Siemens SCALANCE WUM763-1 < V3.0.0; Siemens SCALANCE WUM763-1 < V3.0.0; Siemens SCALANCE WUM763-1 (US) < V3.0.0; Siemens SCALANCE WUM763-1 (US) < V3.0.0; Siemens SCALANCE WUM766-1 < V3.0.0; Siemens SCALANCE WUM766-1 (ME) < V3.0.0; Siemens SCALANCE WUM766-1 (USA) < V3.0.0; Siemens SIMATIC CP 1242-7 V2 All versions < V3.3.46; Siemens SIMATIC CP 1243-1 All versions < V3.3.46; Siemens SIMATIC CP 1243-7 LTE EU All versions < V3.3.46; Siemens SIMATIC CP 1243-7 LTE US All versions < V3.3.46; Siemens SIMATIC CP 1243-8 IRC All versions < V3.3.46; Siemens SIMATIC CP 1542SP-1 IRC >= V2.0, < V2.2.28; Siemens SIMATIC CP 1543-1 All versions < V3.0.22; Siemens SIMATIC CP 1543SP-1 >= V2.0, < V2.2.28; Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL >= V2.0, < V2.2.28; Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC >= V2.0, < V2.2.28; Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL >= V2.0, < V2.2.28; Siemens SIPLUS NET CP 1242-7 V2 All versions < V3.3.46; Siemens SIPLUS NET CP 1543-1 All versions < V3.0.22; Siemens SIPLUS S7-1200 CP 1243-1 All versions < V3.3.46; Siemens SIPLUS S7-1200 CP 1243-1 RAIL All versions < V3.3.46
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
8.8 (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:HOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Attack requirements: Present
  • Privileges required: High
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: High
  • Integrity impact on other systems: High
  • Availability impact on other systems: High
EPSS
2.44% chance of exploitation in 30 days (percentile 85, 2026-11-26)
CWE
CWE-94
Published
Modified

Description

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens RUGGEDCOM RM1224 LTE(4G) EU< V7.2—cvelist
Siemens RUGGEDCOM RM1224 LTE(4G) NAM< V7.2—cvelist
Siemens SCALANCE M804PB< V7.2—cvelist
Siemens SCALANCE M812-1 ADSL-Router< V7.2—cvelist
Siemens SCALANCE M812-1 ADSL-Router< V7.2—cvelist
Siemens SCALANCE M816-1 ADSL-Router< V7.2—cvelist
Siemens SCALANCE M816-1 ADSL-Router< V7.2—cvelist
Siemens SCALANCE M826-2 SHDSL-Router< V7.2—cvelist
Siemens SCALANCE M874-2< V7.2—cvelist
Siemens SCALANCE M874-3< V7.2—cvelist
Siemens SCALANCE M876-3< V7.2—cvelist
Siemens SCALANCE M876-3 (ROK)< V7.2—cvelist
Siemens SCALANCE M876-4< V7.2—cvelist
Siemens SCALANCE M876-4 (EU)< V7.2—cvelist
Siemens SCALANCE M876-4 (NAM)< V7.2—cvelist
Siemens SCALANCE MUM853-1 (EU)< V7.2—cvelist
Siemens SCALANCE MUM856-1 (EU)< V7.2—cvelist
Siemens SCALANCE MUM856-1 (RoW)< V7.2—cvelist
Siemens SCALANCE S615 EEC LAN-Router< V7.2—cvelist
Siemens SCALANCE S615 LAN-Router< V7.2—cvelist
Siemens SCALANCE SC622-2C< V2.3—cvelist
Siemens SCALANCE SC622-2C>= V2.3, < V3.0—cvelist
Siemens SCALANCE SC626-2C< V2.3—cvelist
Siemens SCALANCE SC626-2C>= V2.3, < V3.0—cvelist
Siemens SCALANCE SC632-2C< V2.3—cvelist
Siemens SCALANCE SC632-2C>= V2.3, < V3.0—cvelist
Siemens SCALANCE SC636-2C< V2.3—cvelist
Siemens SCALANCE SC636-2C>= V2.3, < V3.0—cvelist
Siemens SCALANCE SC642-2C< V2.3—cvelist
Siemens SCALANCE SC642-2C>= V2.3, < V3.0—cvelist
Siemens SCALANCE SC646-2C< V2.3—cvelist
Siemens SCALANCE SC646-2C>= V2.3, < V3.0—cvelist
Siemens SCALANCE WAB762-1< V3.0.0—cvelist
Siemens SCALANCE WAM763-1< V3.0.0—cvelist
Siemens SCALANCE WAM763-1 (ME)< V3.0.0—cvelist
Siemens SCALANCE WAM763-1 (US)< V3.0.0—cvelist
Siemens SCALANCE WAM766-1< V3.0.0—cvelist
Siemens SCALANCE WAM766-1 (ME)< V3.0.0—cvelist
Siemens SCALANCE WAM766-1 (US)< V3.0.0—cvelist
Siemens SCALANCE WAM766-1 EEC< V3.0.0—cvelist
Siemens SCALANCE WAM766-1 EEC (ME)< V3.0.0—cvelist
Siemens SCALANCE WAM766-1 EEC (US)< V3.0.0—cvelist
Siemens SCALANCE WUB762-1< V3.0.0—cvelist
Siemens SCALANCE WUB762-1 iFeatures< V3.0.0—cvelist
Siemens SCALANCE WUM763-1< V3.0.0—cvelist
Siemens SCALANCE WUM763-1< V3.0.0—cvelist
Siemens SCALANCE WUM763-1 (US)< V3.0.0—cvelist
Siemens SCALANCE WUM763-1 (US)< V3.0.0—cvelist
Siemens SCALANCE WUM766-1< V3.0.0—cvelist
Siemens SCALANCE WUM766-1 (ME)< V3.0.0—cvelist
Siemens SCALANCE WUM766-1 (USA)< V3.0.0—cvelist
Siemens SIMATIC CP 1242-7 V2All versions < V3.3.46—cvelist
Siemens SIMATIC CP 1243-1All versions < V3.3.46—cvelist
Siemens SIMATIC CP 1243-7 LTE EUAll versions < V3.3.46—cvelist
Siemens SIMATIC CP 1243-7 LTE USAll versions < V3.3.46—cvelist
Siemens SIMATIC CP 1243-8 IRCAll versions < V3.3.46—cvelist
Siemens SIMATIC CP 1542SP-1 IRC>= V2.0, < V2.2.28—cvelist
Siemens SIMATIC CP 1543-1All versions < V3.0.22—cvelist
Siemens SIMATIC CP 1543SP-1>= V2.0, < V2.2.28—cvelist
Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL>= V2.0, < V2.2.28—cvelist
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC>= V2.0, < V2.2.28—cvelist
Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL>= V2.0, < V2.2.28—cvelist
Siemens SIPLUS NET CP 1242-7 V2All versions < V3.3.46—cvelist
Siemens SIPLUS NET CP 1543-1All versions < V3.0.22—cvelist
Siemens SIPLUS S7-1200 CP 1243-1All versions < V3.3.46—cvelist
Siemens SIPLUS S7-1200 CP 1243-1 RAILAll versions < V3.3.46—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-34821. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-34821.md
Affected: Siemens RUGGEDCOM RM1224 LTE(4G) EU < V7.2; Siemens RUGGEDCOM RM1224 LTE(4G) NAM < V7.2; Siemens SCALANCE M804PB < V7.2; Siemens SCALANCE M812-1 ADSL-Router < V7.2; Siemens SCALANCE M812-1 ADSL-Router < V7.2; Siemens SCALANCE M816-1 ADSL-Router < V7.2; Siemens SCALANCE M816-1 ADSL-Router < V7.2; Si…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens RUGGEDCOM RM1224 LTE(4G) EU, Siemens RUGGEDCOM RM1224 LTE(4G) NAM, Siemens SCALANCE M804PB, Siemens SCALANCE M812-1 ADSL-Router, Siemens SCALANCE M816-1 ADSL-Router, Siemens SCALANCE M826-2 SHDSL-Router: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-34821 being exploited?

There is no confirmed exploitation: CVE-2022-34821 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.44% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-34821?

High: CVSS 8.8 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2022-34821?

Siemens RUGGEDCOM RM1224 LTE(4G) EU < V7.2; Siemens RUGGEDCOM RM1224 LTE(4G) NAM < V7.2; Siemens SCALANCE M804PB < V7.2; Siemens SCALANCE M812-1 ADSL-Router < V7.2; Siemens SCALANCE M812-1 ADSL-Router < V7.2; Siemens SCALANCE M816-1 ADSL-Router < V7.2; Siemens SCALANCE M816-1 ADSL-Router < V7.2; Siemens SCALANCE M826-2 SHDSL-Router < V7.2; Siemens SCALANCE M874-2 < V7.2; Siemens SCALANCE M874-3 < V7.2; Siemens SCALANCE M876-3 < V7.2; Siemens SCALANCE M876-3 (ROK) < V7.2; Siemens SCALANCE M876-4 < V7.2; Siemens SCALANCE M876-4 (EU) < V7.2; Siemens SCALANCE M876-4 (NAM) < V7.2; Siemens SCALANCE MUM853-1 (EU) < V7.2; Siemens SCALANCE MUM856-1 (EU) < V7.2; Siemens SCALANCE MUM856-1 (RoW) < V7.2; Siemens SCALANCE S615 EEC LAN-Router < V7.2; Siemens SCALANCE S615 LAN-Router < V7.2; Siemens SCALANCE SC622-2C < V2.3; Siemens SCALANCE SC622-2C >= V2.3, < V3.0; Siemens SCALANCE SC626-2C < V2.3; Siemens SCALANCE SC626-2C >= V2.3, < V3.0; Siemens SCALANCE SC632-2C < V2.3; Siemens SCALANCE SC632-2C >= V2.3, < V3.0; Siemens SCALANCE SC636-2C < V2.3; Siemens SCALANCE SC636-2C >= V2.3, < V3.0; Siemens SCALANCE SC642-2C < V2.3; Siemens SCALANCE SC642-2C >= V2.3, < V3.0; Siemens SCALANCE SC646-2C < V2.3; Siemens SCALANCE SC646-2C >= V2.3, < V3.0; Siemens SCALANCE WAB762-1 < V3.0.0; Siemens SCALANCE WAM763-1 < V3.0.0; Siemens SCALANCE WAM763-1 (ME) < V3.0.0; Siemens SCALANCE WAM763-1 (US) < V3.0.0; Siemens SCALANCE WAM766-1 < V3.0.0; Siemens SCALANCE WAM766-1 (ME) < V3.0.0; Siemens SCALANCE WAM766-1 (US) < V3.0.0; Siemens SCALANCE WAM766-1 EEC < V3.0.0; Siemens SCALANCE WAM766-1 EEC (ME) < V3.0.0; Siemens SCALANCE WAM766-1 EEC (US) < V3.0.0; Siemens SCALANCE WUB762-1 < V3.0.0; Siemens SCALANCE WUB762-1 iFeatures < V3.0.0; Siemens SCALANCE WUM763-1 < V3.0.0; Siemens SCALANCE WUM763-1 < V3.0.0; Siemens SCALANCE WUM763-1 (US) < V3.0.0; Siemens SCALANCE WUM763-1 (US) < V3.0.0; Siemens SCALANCE WUM766-1 < V3.0.0; Siemens SCALANCE WUM766-1 (ME) < V3.0.0; Siemens SCALANCE WUM766-1 (USA) < V3.0.0; Siemens SIMATIC CP 1242-7 V2 All versions < V3.3.46; Siemens SIMATIC CP 1243-1 All versions < V3.3.46; Siemens SIMATIC CP 1243-7 LTE EU All versions < V3.3.46; Siemens SIMATIC CP 1243-7 LTE US All versions < V3.3.46; Siemens SIMATIC CP 1243-8 IRC All versions < V3.3.46; Siemens SIMATIC CP 1542SP-1 IRC >= V2.0, < V2.2.28; Siemens SIMATIC CP 1543-1 All versions < V3.0.22; Siemens SIMATIC CP 1543SP-1 >= V2.0, < V2.2.28; Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL >= V2.0, < V2.2.28; Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC >= V2.0, < V2.2.28; Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL >= V2.0, < V2.2.28; Siemens SIPLUS NET CP 1242-7 V2 All versions < V3.3.46; Siemens SIPLUS NET CP 1543-1 All versions < V3.0.22; Siemens SIPLUS S7-1200 CP 1243-1 All versions < V3.3.46; Siemens SIPLUS S7-1200 CP 1243-1 RAIL All versions < V3.3.46.

Is there a fix for CVE-2022-34821?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2022-34821?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.