Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2022-33324

HIGH 7.5EPSS 79%

Denial-of-Service Vulnerability in Ethernet port of MELSEC iQ-R, iQ-L Series and MELIPC Series

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPU Firmware versions "32" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPU Firmware versions "32" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPU Firmware versions "32" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R04CPU Firmware versions "65" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R08CPU Firmware versions "65" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R16CPU Firmware versions "65" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R32CPU Firmware versions "65" and prior
  • Anyone running Mitsubishi Electric Corporation MELSEC iQ-R Series R120CPU Firmware versions "65" and prior

Vulnerability facts

Affected
Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R04CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R04ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-V Firmware versions "17" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L04HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L08HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L16HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L32HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELIPC Series MI5122-VW Firmware versions "07" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08PSFCPU Firmware versions "08" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16PSFCPU Firmware versions "08" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32PSFCPU Firmware versions "08" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120PSFCPU Firmware versions "08" and prior
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
1.80% chance of exploitation in 30 days (percentile 79, 2026-11-26)
CWE
CWE-404
Published
Modified

Description

Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU Firmware versions "32" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "65" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "29" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-V Firmware versions "17" and prior, Mitsubishi Electric Corporation MELSEC iQ-L Series L04/08/16/32HCPU Firmware versions "05" and prior and Mitsubishi Electric Corporation MELIPC Series MI5122-VW Firmware versions "07" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition in Ethernet communication on the module by sending specially crafted packets. A system reset of the module is required for recovery.

Affected and fixed versions

Package / productAffectedFixedSource
Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPUFirmware versions "32" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPUFirmware versions "32" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPUFirmware versions "32" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R04CPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R08CPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R16CPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R32CPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R120CPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R04ENCPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R08ENCPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R16ENCPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R32ENCPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R120ENCPUFirmware versions "65" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R08SFCPUFirmware versions "29" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R16SFCPUFirmware versions "29" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R32SFCPUFirmware versions "29" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R120SFCPUFirmware versions "29" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-VFirmware versions "17" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-L Series L04HCPUFirmware versions "05" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-L Series L08HCPUFirmware versions "05" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-L Series L16HCPUFirmware versions "05" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-L Series L32HCPUFirmware versions "05" and prior—cvelist
Mitsubishi Electric Corporation MELIPC Series MI5122-VWFirmware versions "07" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R08PSFCPUFirmware versions "08" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R16PSFCPUFirmware versions "08" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R32PSFCPUFirmware versions "08" and prior—cvelist
Mitsubishi Electric Corporation MELSEC iQ-R Series R120PSFCPUFirmware versions "08" and prior—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-33324. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-33324.md
Affected: Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPU Firmware versions "32" and prior; Mitsubishi Electric Cor…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPU, Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPU, Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPU, Mitsubishi Electric Corporation MELSEC iQ-R Series R04CPU, Mitsubishi Electric Corporation MELSEC iQ-R Series R08CPU, Mits…: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-33324 being exploited?

There is no confirmed exploitation: CVE-2022-33324 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.80% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-33324?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2022-33324?

Mitsubishi Electric Corporation MELSEC iQ-R Series R00CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R01CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R02CPU Firmware versions "32" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R04CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120CPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R04ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120ENCPU Firmware versions "65" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120SFCPU Firmware versions "29" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-V Firmware versions "17" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L04HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L08HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L16HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELSEC iQ-L Series L32HCPU Firmware versions "05" and prior; Mitsubishi Electric Corporation MELIPC Series MI5122-VW Firmware versions "07" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R08PSFCPU Firmware versions "08" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R16PSFCPU Firmware versions "08" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R32PSFCPU Firmware versions "08" and prior; Mitsubishi Electric Corporation MELSEC iQ-R Series R120PSFCPU Firmware versions "08" and prior.

Is there a fix for CVE-2022-33324?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2022-33324?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.