# CVE-2022-30236: A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when a…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.2
- **CVSS:** 8.2 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: Low; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.85% (percentile 56, 2026-11-26)
- **CWE:** CWE-669
- **Published:** 2022-06-02T22:45:22.767Z
- **Modified:** 2026-06-17T04:43:19.417Z

## Who should check

- Anyone running Schneider Electric Wiser Smart \>= EER21000, \< 4.5; \>= EER21001, \< 4.5

## Description

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

## Affected and fixed versions

- Schneider Electric Wiser Smart: \>= EER21000, \< 4.5; \>= EER21001, \< 4.5 (cvelist)

## Mitigation

- Upgrade Wiser Smart to 4.5 or later.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2022-30236. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-30236.md
Affected: Schneider Electric Wiser Smart >= EER21000, < 4.5; >= EER21001, < 4.5
Fixed in: Schneider Electric Wiser Smart 4.5, Schneider Electric Wiser Smart 4.5

Steps:
1. Search this machine and project for Schneider Electric Wiser Smart: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2022-30236 being exploited?

There is no confirmed exploitation: CVE-2022-30236 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.85% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2022-30236?

High: CVSS 8.2 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2022-30236?

Schneider Electric Wiser Smart \>= EER21000, \< 4.5; \>= EER21001, \< 4.5.

### Is there a fix for CVE-2022-30236?

Yes. Fixed in Schneider Electric Wiser Smart 4.5, Schneider Electric Wiser Smart 4.5. Upgrade Wiser Smart to 4.5 or later.

### How do I check if I'm affected by CVE-2022-30236?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://www.se.com/ww/en/download/document/SEVD-2022-130-03/>