CVE-2022-29884
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < CPC80 V16.30
- Anyone running Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < CPC80 V16.30
- Anyone running Siemens CP-8021 MASTER MODULE All versions < CPC80 V16.30
- Anyone running Siemens CP-8022 MASTER MODULE WITH GPRS All versions < CPC80 V16.30
Vulnerability facts
- Affected
- Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < CPC80 V16.30; Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < CPC80 V16.30; Siemens CP-8021 MASTER MODULE All versions < CPC80 V16.30; Siemens CP-8022 MASTER MODULE WITH GPRS All versions < CPC80 V16.30
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 1.28% chance of exploitation in 30 days (percentile 70, 2026-11-26)
- CWE
- CWE-772
- Modified
Description
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C | All versions < CPC80 V16.30 | — | cvelist |
| Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C | All versions < CPC80 V16.30 | — | cvelist |
| Siemens CP-8021 MASTER MODULE | All versions < CPC80 V16.30 | — | cvelist |
| Siemens CP-8022 MASTER MODULE WITH GPRS | All versions < CPC80 V16.30 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-29884. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-29884.md Affected: Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < CPC80 V16.30; Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < CPC80 V16.30; Siemens CP-8021 MASTER MODULE All versions < CPC80 V16.30; Siemens CP-8022 MASTER MODULE WITH GPRS All versions < CPC80 V16.30 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C, Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C, Siemens CP-8021 MASTER MODULE, Siemens CP-8022 MASTER MODULE WITH GPRS: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-29884 being exploited?
There is no confirmed exploitation: CVE-2022-29884 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.28% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-29884?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2022-29884?
Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < CPC80 V16.30; Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < CPC80 V16.30; Siemens CP-8021 MASTER MODULE All versions < CPC80 V16.30; Siemens CP-8022 MASTER MODULE WITH GPRS All versions < CPC80 V16.30.
Is there a fix for CVE-2022-29884?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-29884?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.