CVE-2022-26389

HIGH 7.7EPSS 31%

Improper Access Control Vulnerability in ELI Electrocardiograph Devices

Mitigation

  • Vendor workaround: Hillrom recommends the following workarounds to help reduce risk:
  • * Apply proper network and physical security controls.
  • * Ensure a unique encryption key is configured for ELI Link and Cardiograph.
  • * Where possible, use a firewall to prevent communication on Port 21
  • FTP service, Port 22 SSH (Secure Shell Connection), and Port 23 Telnet
  • service.

Who should check

  • Anyone running Baxter/ Hillrom ELI 380 Resting Electrocardiograph <= 2.6.0
  • Anyone running Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph <= 2.3.1
  • Anyone running Welch Allyn ELI 250c/BUR 250c Resting Electrocardiograph <= 2.1.2
  • Anyone running Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph <= 2.2.0

Vulnerability facts

Affected
Baxter/ Hillrom ELI 380 Resting Electrocardiograph <= 2.6.0; Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph <= 2.3.1; Welch Allyn ELI 250c/BUR 250c Resting Electrocardiograph <= 2.1.2; Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph <= 2.2.0
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
7.7 (v3.1, CNA)CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: High
  • Privileges required: Low
  • User interaction: None
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: Low
  • Integrity impact: Low
  • Availability impact: High
EPSS
0.45% chance of exploitation in 30 days (percentile 31, 2026-11-26)
CWE
CWE-284
Published
Modified

Description

An improper access control vulnerability may allow privilege escalation.This issue affects:  * ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior;  * ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior;  * ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior;  * ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior.

Affected and fixed versions

Package / productAffectedFixedSource
Baxter/ Hillrom ELI 380 Resting Electrocardiograph<= 2.6.0—cvelist
Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph<= 2.3.1—cvelist
Welch Allyn ELI 250c/BUR 250c Resting Electrocardiograph<= 2.1.2—cvelist
Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph<= 2.2.0—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-26389. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-26389.md
Affected: Baxter/ Hillrom ELI 380 Resting Electrocardiograph <= 2.6.0; Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph <= 2.3.1; Welch Allyn ELI 250c/BUR 250c Resting Electrocardiograph <= 2.1.2; Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph <= 2.2.0
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Baxter/ Hillrom ELI 380 Resting Electrocardiograph, Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph, Welch Allyn ELI 250c/BUR 250c Resting Electrocardiograph, Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-26389 being exploited?

There is no confirmed exploitation: CVE-2022-26389 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.45% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-26389?

High: CVSS 7.7 (v3.1, scored by CNA). Remote, login needed. The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2022-26389?

Baxter/ Hillrom ELI 380 Resting Electrocardiograph <= 2.6.0; Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph <= 2.3.1; Welch Allyn ELI 250c/BUR 250c Resting Electrocardiograph <= 2.1.2; Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph <= 2.2.0.

Is there a fix for CVE-2022-26389?

No fixed version is listed in the sources yet. Vendor workaround: Hillrom recommends the following workarounds to help reduce risk: * Apply proper network and physical security controls. * Ensure a unique encryption key is configured for ELI Link and Cardiograph. * Where possible, use a firewall to prevent communication on Port 21 FTP service, Port 22 SSH (Secure Shell Connection), and Port 23 Telnet service.

How do I check if I'm affected by CVE-2022-26389?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors