CVE-2022-24352
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link AC1…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running TP-Link AC1750 prior to 211210
Vulnerability facts
- Affected
- TP-Link AC1750 prior to 211210
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.8 (v3.0, CNA)CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.73% chance of exploitation in 30 days (percentile 50, 2026-11-26)
- CWE
- CWE-125
- Modified
Description
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link AC1750 prior to 211210 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the NetUSB.ko kernel module. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-15773.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| TP-Link AC1750 | prior to 211210 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-24352. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-24352.md Affected: TP-Link AC1750 prior to 211210 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for TP-Link AC1750: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-24352 being exploited?
There is no confirmed exploitation: CVE-2022-24352 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.73% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-24352?
High: CVSS 8.8 (v3.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2022-24352?
TP-Link AC1750 prior to 211210.
Is there a fix for CVE-2022-24352?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-24352?