CVE-2022-24323

MEDIUM 5.3EPSS 46%

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of c…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Schneider Electric EcoStruxure Process Expert V2021 and prior
  • Anyone running Schneider Electric EcoStruxure Control Expert V15.0 SP1 and prior

Vulnerability facts

Affected
Schneider Electric EcoStruxure Process Expert V2021 and prior; Schneider Electric EcoStruxure Control Expert V15.0 SP1 and prior
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
5.3 (v3.1, CNA)CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: High
  • Privileges required: None
  • User interaction: Required
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
0.66% chance of exploitation in 30 days (percentile 46, 2026-11-26)
CWE
CWE-754
Published
Modified

Description

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)

Affected and fixed versions

Package / productAffectedFixedSource
Schneider Electric EcoStruxure Process ExpertV2021 and prior—cvelist
Schneider Electric EcoStruxure Control ExpertV15.0 SP1 and prior—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-24323. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-24323.md
Affected: Schneider Electric EcoStruxure Process Expert V2021 and prior; Schneider Electric EcoStruxure Control Expert V15.0 SP1 and prior
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric EcoStruxure Process Expert, Schneider Electric EcoStruxure Control Expert: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-24323 being exploited?

There is no confirmed exploitation: CVE-2022-24323 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.66% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-24323?

Medium: CVSS 5.3 (v3.1, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work. The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2022-24323?

Schneider Electric EcoStruxure Process Expert V2021 and prior; Schneider Electric EcoStruxure Control Expert V15.0 SP1 and prior.

Is there a fix for CVE-2022-24323?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2022-24323?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors