CVE-2022-23705
A security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Ar…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays 5.0.10.0 and earlier
Vulnerability facts
- Affected
- HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays 5.0.10.0 and earlier
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- EPSS
- 1.28% chance of exploitation in 30 days (percentile 70, 2026-11-26)
- Modified
Description
A security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Arrays, and HPE Nimble Storage Secondary Flash Arrays which could potentially allow the upload, but not execution, of unauthorized update binaries to the array. HPE has made the following software updates to resolve the vulnerability in HPE Nimble Storage: 5.0.10.100 or later, 5.2.1.0 or later, 6.0.0.100 or later.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays | 5.0.10.0 and earlier | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-23705. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-23705.md Affected: HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays 5.0.10.0 and earlier Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-23705 being exploited?
There is no confirmed exploitation: CVE-2022-23705 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.28% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-23705?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2022-23705?
HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays 5.0.10.0 and earlier.
Is there a fix for CVE-2022-23705?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-23705?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.