Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2022-23448

HIGH 7.8EPSS 16%

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Mana…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SIMATIC Energy Manager Basic All versions < V7.3 Update 1
  • Anyone running Siemens SIMATIC Energy Manager PRO All versions < V7.3 Update 1

Vulnerability facts

Affected
Siemens SIMATIC Energy Manager Basic All versions < V7.3 Update 1; Siemens SIMATIC Energy Manager PRO All versions < V7.3 Update 1
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.8 (v3.1, NVD)CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.31% chance of exploitation in 30 days (percentile 16, 2026-11-26)
CWE
CWE-732
Published
Modified

Description

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SIMATIC Energy Manager BasicAll versions < V7.3 Update 1—cvelist
Siemens SIMATIC Energy Manager PROAll versions < V7.3 Update 1—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-23448. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-23448.md
Affected: Siemens SIMATIC Energy Manager Basic All versions < V7.3 Update 1; Siemens SIMATIC Energy Manager PRO All versions < V7.3 Update 1
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMATIC Energy Manager Basic, Siemens SIMATIC Energy Manager PRO: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-23448 being exploited?

There is no confirmed exploitation: CVE-2022-23448 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.31% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-23448?

High: CVSS 7.8 (v3.1, scored by NVD). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2022-23448?

Siemens SIMATIC Energy Manager Basic All versions < V7.3 Update 1; Siemens SIMATIC Energy Manager PRO All versions < V7.3 Update 1.

Is there a fix for CVE-2022-23448?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2022-23448?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors