CVE-2022-22508
CODESYS V3: Improper Input Validation
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running CODESYS V3 CODESYS Control RTE (SL) >= V0.0.0.0, < V3.5.18.40
- Anyone running CODESYS V3 CODESYS Control RTE (for Beckhoff CX) SL >= V0.0.0.0, < V3.5.18.40
- Anyone running CODESYS V3 CODESYS Control Win (SL) >= V0.0.0.0, < V3.5.18.40
- Anyone running CODESYS V3 CODESYS HMI (SL) >= V0.0.0.0, < V3.5.18.40
- Anyone running CODESYS V3 CODESYS Control Runtime System Toolkit >= V0.0.0.0, < V3.5.18.40
- Anyone running CODESYS V3 CODESYS Control for BeagleBone SL >= V0.0.0.0, < V4.7.0.0
- Anyone running CODESYS V3 CODESYS Control for emPC-A/iMX6 SL >= V0.0.0.0, < V4.7.0.0
- Anyone running CODESYS V3 CODESYS Control for IOT2000 SL >= V0.0.0.0, < V4.7.0.0
Vulnerability facts
- Affected
- CODESYS V3 CODESYS Control RTE (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control RTE (for Beckhoff CX) SL >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control Win (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS HMI (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control Runtime System Toolkit >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control for BeagleBone SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for emPC-A/iMX6 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for IOT2000 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for Linux SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for PFC100 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for PFC200 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for PLCnext SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for Raspberry Pi SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for WAGO Touch Panels 600 SL >= V0.0.0.0, < V4.7.0.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 4.3 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: Low
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Low
- EPSS
- 0.82% chance of exploitation in 30 days (percentile 54, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| CODESYS V3 CODESYS Control RTE (SL) | >= V0.0.0.0, < V3.5.18.40 | — | cvelist |
| CODESYS V3 CODESYS Control RTE (for Beckhoff CX) SL | >= V0.0.0.0, < V3.5.18.40 | — | cvelist |
| CODESYS V3 CODESYS Control Win (SL) | >= V0.0.0.0, < V3.5.18.40 | — | cvelist |
| CODESYS V3 CODESYS HMI (SL) | >= V0.0.0.0, < V3.5.18.40 | — | cvelist |
| CODESYS V3 CODESYS Control Runtime System Toolkit | >= V0.0.0.0, < V3.5.18.40 | — | cvelist |
| CODESYS V3 CODESYS Control for BeagleBone SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for emPC-A/iMX6 SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for IOT2000 SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for Linux SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for PFC100 SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for PFC200 SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for PLCnext SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for Raspberry Pi SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
| CODESYS V3 CODESYS Control for WAGO Touch Panels 600 SL | >= V0.0.0.0, < V4.7.0.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-22508. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-22508.md Affected: CODESYS V3 CODESYS Control RTE (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control RTE (for Beckhoff CX) SL >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control Win (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS HMI (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control Runtime Syst… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for CODESYS V3 CODESYS Control RTE (SL), CODESYS V3 CODESYS Control RTE (for Beckhoff CX) SL, CODESYS V3 CODESYS Control Win (SL), CODESYS V3 CODESYS HMI (SL), CODESYS V3 CODESYS Control Runtime System Toolkit, CODESYS V3 CODESYS Control for BeagleBone SL: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-22508 being exploited?
There is no confirmed exploitation: CVE-2022-22508 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.82% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-22508?
Medium: CVSS 4.3 (v3.1, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2022-22508?
CODESYS V3 CODESYS Control RTE (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control RTE (for Beckhoff CX) SL >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control Win (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS HMI (SL) >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control Runtime System Toolkit >= V0.0.0.0, < V3.5.18.40; CODESYS V3 CODESYS Control for BeagleBone SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for emPC-A/iMX6 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for IOT2000 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for Linux SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for PFC100 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for PFC200 SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for PLCnext SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for Raspberry Pi SL >= V0.0.0.0, < V4.7.0.0; CODESYS V3 CODESYS Control for WAGO Touch Panels 600 SL >= V0.0.0.0, < V4.7.0.0.
Is there a fix for CVE-2022-22508?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2022-22508?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.