Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2022-2179

MEDIUM 6.5EPSS 60%

ICSA-22-188-01 Rockwell Automation MicroLogix Improper Restriction of Rendered UI Layers or Frames

Mitigation

  • Vendor workaround: Rockwell Automation encourages those using the affected software to implement the mitigations below to minimize risk. Additionally, Rockwell Automation encourages users to combine risk mitigations with security best practices (also provided below) to deploy a defense-in-depth strategy.
  • Disable the web server where possible (this component is an optional feature and disabling it will not disrupt the intended use of the device).
  • Configure firewalls to disallow network communication through HTTP/Port 80
  • If applying the mitigations noted above are not possible, please see Rockwell Automation’s Knowledgebase article QA43240 Security Best Practices.
  • For more information, please see the industrial security advisory from Rockwell Automation.

Who should check

  • Anyone running Rockwell Automation MicroLogix 1400 >= unspecified, <= 21.007
  • Anyone running Rockwell Automation MicroLogix 1100 All versions

Vulnerability facts

Affected
Rockwell Automation MicroLogix 1400 >= unspecified, <= 21.007; Rockwell Automation MicroLogix 1100 All versions
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
6.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: Required
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: None
  • Availability impact: None
EPSS
0.95% chance of exploitation in 30 days (percentile 60, 2026-11-26)
CWE
CWE-1021
Published
Modified

Description

The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.

Affected and fixed versions

Package / productAffectedFixedSource
Rockwell Automation MicroLogix 1400>= unspecified, <= 21.007—cvelist
Rockwell Automation MicroLogix 1100All versions—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-2179. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-2179.md
Affected: Rockwell Automation MicroLogix 1400 >= unspecified, <= 21.007; Rockwell Automation MicroLogix 1100 All versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Rockwell Automation MicroLogix 1400, Rockwell Automation MicroLogix 1100: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-2179 being exploited?

There is no confirmed exploitation: CVE-2022-2179 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.95% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-2179?

Medium: CVSS 6.5 (v3.1, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2022-2179?

Rockwell Automation MicroLogix 1400 >= unspecified, <= 21.007; Rockwell Automation MicroLogix 1100 All versions.

Is there a fix for CVE-2022-2179?

No fixed version is listed in the sources yet. Vendor workaround: Rockwell Automation encourages those using the affected software to implement the mitigations below to minimize risk. Additionally, Rockwell Automation encourages users to combine risk mitigations with security best practices (also provided below) to deploy a defense-in-depth strategy. Disable the web server where possible (this component is an optional feature and disabling it will not disrupt the intended use of the device). Configure firewalls to disallow network communication through HTTP/Port 80 If applying the mitigations noted above are not possible, please see Rockwell Automation’s Knowledgebase article QA43240 Security Best Practices. For more information, please see the industrial security advisory from Rockwell Automation.

How do I check if I'm affected by CVE-2022-2179?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors