Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2022-2102

CRITICAL 9.4EPSS 58%

Secheron SEPCOS Control and Protection Relay

Mitigation

  • Upgrade SEPCOS Control and Protection Relay firmware package to 1.23.21 or later.
  • Vendor workaround: Additional workarounds are suggested to help reduce the risk:
  • Configure the network such that PLC communications are strictly limited to only the devices required to perform its functions.
  • Limit remote access and close Ports 80 and 443 at the switch level.
  • Only use approved devices to connect to the PLCs. Do not connect personal peripherals (USB sticks, hotspots) to approved devices.
  • Check device logs during periodic maintenance for unauthorized changes or access.

Who should check

  • Anyone running Secheron SEPCOS Control and Protection Relay firmware package >= All versions, < 1.23.21

Vulnerability facts

Affected
Secheron SEPCOS Control and Protection Relay firmware package >= All versions, < 1.23.21
Fixed in
Secheron SEPCOS Control and Protection Relay firmware package 1.23.21
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.4 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: Low
  • Integrity impact: High
  • Availability impact: High
EPSS
0.92% chance of exploitation in 30 days (percentile 58, 2026-11-26)
CWE
CWE-841
Published
Modified

Description

Controls limiting uploads to certain file extensions may be bypassed. This could allow an attacker to intercept the initial file upload page response and modify the associated code. This modified code can be forwarded and used by a script loaded later in the sequence, allowing for arbitrary file upload into a location where PHP scripts may be executed.

Affected and fixed versions

Package / productAffectedFixedSource
Secheron SEPCOS Control and Protection Relay firmware package>= All versions, < 1.23.21—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-2102. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-2102.md
Affected: Secheron SEPCOS Control and Protection Relay firmware package >= All versions, < 1.23.21
Fixed in: Secheron SEPCOS Control and Protection Relay firmware package 1.23.21

Steps:
1. Search this machine and project for Secheron SEPCOS Control and Protection Relay firmware package: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-2102 being exploited?

There is no confirmed exploitation: CVE-2022-2102 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.92% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-2102?

Critical: CVSS 9.4 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2022-2102?

Secheron SEPCOS Control and Protection Relay firmware package >= All versions, < 1.23.21.

Is there a fix for CVE-2022-2102?

Yes. Fixed in Secheron SEPCOS Control and Protection Relay firmware package 1.23.21. Upgrade SEPCOS Control and Protection Relay firmware package to 1.23.21 or later. Vendor workaround: Additional workarounds are suggested to help reduce the risk: Configure the network such that PLC communications are strictly limited to only the devices required to perform its functions. Limit remote access and close Ports 80 and 443 at the switch level. Only use approved devices to connect to the PLCs. Do not connect personal peripherals (USB sticks, hotspots) to approved devices. Check device logs during periodic maintenance for unauthorized changes or access.

How do I check if I'm affected by CVE-2022-2102?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors